OPTIMOD-PC
INSTALLATION
2-37
A)
Open the ROCK-MEDIUM factory processing preset.
a)
On the Orban Control application, choose F
ILE
/O
PEN
P
RESET
.
The Open Preset dialog box
appears.
b)
Click R
OCK
-M
EDIUM
in the preset
list.
The R
OCK
-M
EDIUM
preset be-
comes active. The dialog box
remains open until you explic-
itly close it by clicking D
ONE
.
B)
Calibrate using tone—feed a test
tone at your reference level to
OPTIMOD-PC.
[Skip this step if you are using
program material to calibrate
OPTIMOD-PC to your standard studio level. Skip to step (C) on page 2-37]
a)
If you are not using a studio level controller, feed a tone through your
console or mixer at the level at which you normally peak program material
(typically 0
VU if your console uses VU meters).
If you are using a studio level controller that performs an AGC function,
such as another OPTIMOD-PC or an Orban 6300, adjust it for normal
operation.
b)
In the I/O Mixer, click the C
ONFIGURATION
tab.
c)
Click the P
ROCESSOR MIXER
tab.
d)
Set the A
NALOG
L/R
I
NPUT
fader to make the M
IXER
O
UTPUT
meter indicate
–20dBfs.
For more information, refer to the notes under step 1 on page 2-35.
e)
Note the setting of the A
NALOG
L/R
I
NPUT
fader. Click the D
IRECT
M
IXER
tab
and set the A
NALOG
L/R
I
NPUT
fader to the same value.
f)
Skip to step 5 on page 2-38.
C)
Calibrate using program: Feed normal program material to OPTIMOD-PC’s an-
alog input.
[Skip this step if you are using tone to calibrate OPTIMOD-PC to your
standard studio level—see step (B) above.]
a)
Play program material from your studio, peaking at the level to which you
normally peak program material (typically 0 VU if your console uses VU
meters).
b)
In the Mixer application, click the C
ONFIGURATION
tab.
c)
Verify that
AGC
is set to
E
NABLED
.