6-6
TECHNICAL DATA
ORBAN MODEL 8382
1.
Remote Interface and RS-232 Interfaces
Located on base board
A remote interface connector and circuitry implements remote control of certain
operating modes; Model 8382 OPTIMOD-TV has eight remote contact closure in-
puts.
A valid remote signal is a momentary pulse of current flowing through remote
signal pins. Current must flow consistently for 50msec for the signal to be inter-
preted as valid. Generally, the 8382 will respond to the most recent control op-
eration, regardless of whether it came from the front panel, remote interface, or
RS-232.
Component-Level Description:
After being current limited by resistors, the GPI control signals are applied to
two quad optoisolators, U10, 12, and then to the control circuitry.
Octal driver U1 buffers the RS-232 port, which is located on a small daughter
board.
U10, 12 and U1 are socketed for easy field replacement in the event of over-
load, lightning damage, etc. All other circuitry is surface-mount and is not
field-repairable.
2.
Switch Matrix and LED Indicators
Located on display board
Eleven front panel pushbutton switches are arranged in a matrix, configured as
three columns and four rows. These switches are the primary element of the
physical user interface to the 8382 control software. The host microprocessor
controls the system setup and function of the DSP according to the switch / ro-
tary encoder entered commands, the AES status bits from the digital input signal,
the RS-232, and the remote control interface status. The microprocessor updates
the LED control status indicators accordingly.
Component-Level Description:
S1-S11 are the front panel pushbutton switches. CR11-CR15 are the front panel
LED control status indicators. The control microprocessor communicates with
these components through the ISA bus, which is buffered via IC3.
3.
LED Meter Circuits
Located on display board
The meter LEDs are arranged in an 8x16 matrix, in rows and columns.
Each row of LEDs in the matrix has a 1/8 duty cycle ON time. The rows are multi-
plexed at a fast rate so that the meters appear continuously illuminated. Via the
ISA bus, the DSP sends meter data values to the control microprocessor, which
Summary of Contents for Optimod-TV 8382
Page 22: ......
Page 108: ......
Page 162: ......
Page 174: ......
Page 213: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 25...
Page 219: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 31 CPU Module...
Page 225: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 37 RS232 BOARD PARTS LOCATOR...
Page 227: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 39 POWER SUPPLY PARTS LOCATOR...
Page 229: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 41 8382 I O Board Parts Locator...
Page 234: ...6 46 TECHNICAL DATA ORBAN MODEL 8382 DSP BOARD PARTS LOCATOR DRAWING 32170 000 14...
Page 242: ...6 54 TECHNICAL DATA ORBAN MODEL 8382 DISPLAY BOARD PARTS LOCATOR...
Page 243: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 55 DISPLAY BOARD...