OPTIMOD-TV DIGITAL
INSTALLATION
2-3
AC power passes through an IEC-standard mains connector and an RF fil-
ter designed to meet the standards of all international safety authorities.
The power cord is terminated in a “U-ground” plug (USA standard), or
CEE7 / 7 plug (Continental Europe), as appropriate to your 8382’s Model
Number. The green / yellow wire is connected directly to the 8382 chassis.
If you need to change the plug to meet your country’s standard and you
are qualified to do so, see Figure 2-1. Otherwise, purchase a new mains
cord with the correct line plug attached.
3.
Set Ground Lift switch.
The
G
ROUND
L
IFT
switch is located on the rear panel.
The
G
ROUND
L
IFT
switch is shipped from the factory in the
GROUND
position, (to
connect the 8382’s circuit ground to its chassis ground). This is almost always op-
timum
.
4.
Mount the 8382 in a rack.
The 8382 requires two standard rack units (3 ½ inches / 12.7 cm).
There should be a good ground connection between the rack and the 8382 chas-
sis—check this with an ohmmeter to verify that the resistance is less than 0.5
.
Mounting the unit over large heat-producing devices (such as a vacuum-tube
power amplifier) may shorten component life and is not recommended. Ambient
temperature should not exceed 45
C (113
F) when equipment is powered.
Equipment life will be extended if the unit is mounted away from sources of vi-
bration, such as large blowers and is operated as cool as possible.
5.
Connect inputs and outputs.
See the hookup and grounding information on the following pages.
TOPIC PAGE
Audio Input and Audio Output Connections.............................................2-5
AES3 Digital Input and Output ...................................................................2-7
Grounding ...................................................................................................2-8
6.
Connect remote control interface. (optional)
For a full listing of 8382’s extensive remote control provisions, refer to
Remote
Control Interface Programming
on page 2-32.
Optically isolated remote control connections are terminated in a type DB-25
male connector located on the rear panel. It is wired according to Figure 2-2. To
select the desired function, apply a 5-12V AC or DC pulse between the appropri-
ate
REMOTE
INTERFACE
terminals. The (
) terminals can be connected together
and then connected to ground at pin 1 to create a Remote Common. A current-
l12VDC source is available on pin 25. If you use 48V, connect a 2k
Summary of Contents for Optimod-TV 8382
Page 22: ......
Page 108: ......
Page 162: ......
Page 174: ......
Page 213: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 25...
Page 219: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 31 CPU Module...
Page 225: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 37 RS232 BOARD PARTS LOCATOR...
Page 227: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 39 POWER SUPPLY PARTS LOCATOR...
Page 229: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 41 8382 I O Board Parts Locator...
Page 234: ...6 46 TECHNICAL DATA ORBAN MODEL 8382 DSP BOARD PARTS LOCATOR DRAWING 32170 000 14...
Page 242: ...6 54 TECHNICAL DATA ORBAN MODEL 8382 DISPLAY BOARD PARTS LOCATOR...
Page 243: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 55 DISPLAY BOARD...