Minimum space for installation (Fig 1)
Choose a location for mounting the fan where the blades are clear from all obstructions and maintain a
minimum of 2.3 meters from the floor, 0.6 meter away from the wall.
Fig 1
2.
Bracket installation
(1)
For wooden ceiling, fix the bracket on the beam using 1.5 inches wooden threaded screws. (Fig 2)
(2)
For cement ceiling, first use
φ
8mm impact drilling bit to drill two holes to fit the expansion screws,
then secure the bracket on the ceiling by tightening M6 expansion screws. (Fig 3)
Fig 2 Fig 3
Note: After the bracket is secured, make sure the selected ceiling location with the fixings is capable of
bearing a minimum weight/gravity of 50 kg to ensure safety.
Note: Please select the appropriate type of screws to fix the bracket. Do not fix the bracket directly on
plywood to avoid screw loosening that causes danger.