background image

CA 07260 A IN 

 

 

 

13 

 

2.

 

A straight, short duct run will allow the hood to perform most efficiently. 

3.

 

Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as 
possible. Larger ducting may be required for best performance with longer duct runs. 

4.

 

The outside of the hood for the duct is 150mm. However we provide a reducer from 150mm to 120mm 
to use a smaller duct of 120mm. 

5.

 

The duct shouldn’t discharge into a flue for exhausting fumes from gas or other flues appliances. 

 

ELECTRICAL CONNECTION 

 
-  Electric  connection  should  be  done  by  qualified  person  according  current  regulation.  Disconnect  main 
power of house before connect the hood. 
- If supplied cord is damage, should be replaced by the maker or technical service. 
- Don’t use a plug or extension whose are not supplied with the hood. 
 

INSTALLATION 
 

The  hood  is  designed  to  work  with  a  duct  of  150mm  of  diameter.  If  you  use  a  120mm  duct  place  the 
supplied reducer. 

 

DUCT INSTALLATION 

 
Use an outlet exhaust duct with: minimum indispensable length, minimum possible bends (maximum angle 
90º), certified material and as smooth as possible inside. 
 

FITTING HOOD TO FURNITURE 

 

1.

 

Before attaching the hood to the cabinet, make a 165mm diameter hole for the 150mm or 135mm tube 
for the 120mm tube. 

2.

 

Make sure that the hole in the cabinet has the dimensions of the hood 490X258cm. 

3.

 

In any case, check the position of the hood before installing it, so that it can be connected to the nearest 
outlet without problems, in case you have to make a hole in the cabinet to pass the cable. 

4.

 

Unscrew the visible screws located on each side of the hood and remove the front, 8 holes will be visible. 

5.

 

Lift the hood and place it in its position in the cabinet. Fix the hood to the cabinet by screwing it through 
the 8 holes mentioned above. Replace the front of the hood and fix it with its 2 corresponding screws. 

6.

 

Make the electrical connection. 

7.

 

The installation has been completed. 

Summary of Contents for CA 07260 A IN

Page 1: ...los mejores resultados y la m xima seguridad de uso Read this manual carefully before running this appliance and save it for reference in order to obtain the best results and ensure safe use Veuillez...

Page 2: ...visi n o formaci n apropiadas respecto al uso del aparato de una manera segura y comprenden los peligros que implica Los ni os no deben jugar con el aparato La limpieza y el mantenimiento a realizar p...

Page 3: ...de necesitar una copia del manual de instrucciones puede solicitarla por correo electr nico a trav s de sonifer sonifer es 14 ADVERTENCIA En caso de mala utilizaci n existe riesgo de posibles heridas...

Page 4: ...can una distancia superior se deben tener en cuenta La distancia de 65cm no puede reducirse Los reglamentos respecto a la evacuaci n del aire han de ser respetados La presi n negativa en el ambiente n...

Page 5: ...esgo de incendio Compruebe constantemente la fritura de la comida para evitar que el aceite sobrecalentado se convierta en un riesgo de incendio PRECAUCION Las bombillas de esta campana se han dise ad...

Page 6: ...odr usar tambi n tubo de 120mm de di metro 5 El tubo no debe ir a para a una chimenea para humos de aparatos a gas u otros combustibles CONEXI N ELECTRICA La conexi n el ctrica la debe realizar una pe...

Page 7: ...ci n se ha completado Aviso La salida del tubo no debe ir a una chimenea extractora de humos de aparatos a gas u otros combustibles Si las instrucciones de su encimera a gas indican que la distancia d...

Page 8: ...j a est n en contacto mucho tiempo con el acero inoxidable ya que podr an perjudicarlo Aclare con agua despu s de su uso y s quela con un trapo suave CARACTER STICAS T CNICAS Modelo CA 07260 A IN Volt...

Page 9: ...ning use of the appliance in a safe way and understand the hazards involved Children must never play with the appliance Cleaning and user maintenance must never be carried out by children without supe...

Page 10: ...f misuse there is a risk of possible injury Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend on the air in the environment and are supplied by ot...

Page 11: ...0 5 bar Provide adequate ventilation in the environment for a safe operation of the cooker hood Follow the local laws applicable for external air evacuation Appliance shall only be used with rated vol...

Page 12: ...xterior surfaces of the hood prior to final installation Note 2 At least two people will be required to mount the hood DESCRIPTION AND CONNECTIONS The hood is only installed in the ducting version Cau...

Page 13: ...duct of 150mm of diameter If you use a 120mm duct place the supplied reducer DUCT INSTALLATION Use an outlet exhaust duct with minimum indispensable length minimum possible bends maximum angle 90 cer...

Page 14: ...his filter is not washable cannot be regenerated and should be replaced approximately every 3 months of operation or more frequently in the case on higher using 1 Remove metallic filter to install the...

Page 15: ...al of old electrical appliances The European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE requires that old household electrical appliances must not be disposed of in the nor...

Page 16: ...ur l usage de cet appareil en toute s curit et de compr hension des risques impliqu s Les enfants ne doivent pas jouer avec l appareil Le nettoyage et la maintenance ne doivent pas tr s effectu s par...

Page 17: ...e mail sonifer sonifer es 14 AVERTISSEMENT En cas de mauvaise utilisation de l appareil il ya un risque de blessure Faites attention quand la hotte aspirante fonctionne simultan ment avec une flamme o...

Page 18: ...l air doivent tre respect es La pression n gative dans l air ambiant ne doit pas d passer 4 Pa 4 10 5 bar Fournir une bonne ventilation dans la pi ce pour ne pas courir de risques en utilisant la hott...

Page 19: ...la cuisson Ils ne sont pas adapt s pour l clairage des m nages DIMENSIONS INSTALLATION ET UTILISATION Remarque 1 Sur les hottes en acier inoxydable retirez soigneusement le film protecteur en plastiqu...

Page 20: ...ent la r glementation en vigueur D branchez l alimentation principale de la maison avant de brancher la hotte Si le cordon fourni est endommag il doit tre remplac par le fabricant ou le service techni...

Page 21: ...de l air vacu doit tre respect e OP RATION Cette hotte a deux interrupteurs sur le panneau frontal Un pour la lumi re 2 positions on et off et l autre pour la puissance d extraction 4 positions 0 OFF...

Page 22: ...e pendant une longue p riode car ils pourraient l endommager Rincer l eau apr s utilisation et s cher avec un chiffon doux CARACT RISTIQUES TECHNIQUES Mod le CA 07260 A IN Tension 220 240V Frecuencie...

Page 23: ...es N o deixe que crian as brinquem com o aparelho N o permita a limpeza e manuten o do aparel ho pelo utilizador a crian as sem vigil ncia 2 As crian as dever o ser supervisionadas para se assegurar d...

Page 24: ...o h um risco de poss veis les es Tome especial aten o quando o exaustor se encontra em funcionamento simultaneamente com uma lareira ou salamandra visto estes para funcionar necessitam de livre circul...

Page 25: ...mbust vel A dist ncia m nima entre os elementos de cozedura e a parte inferior da capa dever ser de pelo menos 65 cent metros se o capuz instalado num elemento de cozinhar a g s Se as instru es de ins...

Page 26: ...e metal 1 Decida onde o duto ser executado entre o capuz e o exterior 2 Uma passagem de dutos curta e reta permitir que o cap funcione com mais efici ncia 3 Longa dutos cotovelos e transi es reduzir o...

Page 27: ...austor ao gabinete fa a um orif cio de 165 mm de di metro para o tubo de 150 mm ou 135 mm para o tubo de 120 mm 2 Certifique se de que o orif cio no gabinete tenha as dimens es do cap 490X258cm 3 Em q...

Page 28: ...gire o no sentido hor rio e remova o SUBSTITUI O DE LUZES Este capuz tem 2 luzes LED que t m uma dura o alta e normal que n o estraguem Se isso n o funcionar pe a a uma pessoa qualificada para alter l...

Page 29: ...o e reciclagem dos materiais que os comp em e impedir potenciais danos para a sa de humana e para o ambiente O s mbolo constitu do por um contendor de lixo barrado com uma cruz deve ser colocado em to...

Reviews: