PHE 75/PHE 80
33
12. Leak Check.
Leak testing:
This must be done before initial use, annually,and whenever any gas
Components are replaced or serviced. Do not smoke while performing this test, and remove
all sources of ignition. See Leak Testing Diagram for areas to check. Turn all burner controls
to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections
of the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced
with one recommended by the Customer Care department and have the patio heater
inspected by a certified gas installer.
If the leak cannot be stopped,immediately shut off the gas supply, disconnect it,and
have the patio heater inspected by a certified gas installer or dealer. Do not use the patio
heater until the leak has been corrected.
WARNING!
A leak test must be performed annually and each time a cylinder is
hooked up or if a part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks
or open flames are in the area while you check for leaks. Sparks or open flames will
result in a fire or explosion, damage to property,serious bodily injury,or death.
Hose / Regulator
connection
Regulator / Cylinder
connection