PHE 85
15
To check the hose at least once per month
,
each time the
cylinder is changed
,
or each time before long time no use.
If it shows signs of cracking, splitting or other deterioration
it shall be exchanged for new hose of the same length and
of the equivalent quality.
The use of this appliance in enclosed areas can be
dangerous and is PROHIBITED;
Read the instructions before using this appliance. The
appliance must be installed in accordance with the
instructions and
local regulations.
HEATER STAND AND LOCATION
The heater is primarily for outdoor use only. Always ensure that
adequate
fresh air ventilation is provided.
Always maintain proper clearance to non protected combustible materials
i.e. top 100 cm and sides 100 cm minimum.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas where
gasoline or other flammable liquids or vapors are stored.
To protect heater from strong wind, anchor the base securely to the ground
with screws.
GAS REQUIREMENTS
Use propane, butane or their mixtures gas only. We strongly recommend to use propane, because it has a
lower freezing point, suitable to be outdoor. The pressure regulator and hose assembly to be used must
conform to local standard codes. The installation must conform to local codes, or in the absence of local
codes, with the standard for the storage and handling of liquid petroleum gases. A dented, rusted or
damaged tank may be hazardous and should be checked by your tank supplier. Never use a tank with a
damaged valve connection.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater. Make a soap solution of one part liquid detergent and one part water.
The soap solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a