ORBINOX reserves the right to change specifications without notice.
ORBINOX CANADA, ORBINOX USA, ORBINOX SPAIN, ORBINOX UK, ORBINOX FRANCE, ORBINOX GERMANY, ORBINOX INDIA, ORBINOX CHINA
WWW.ORBINOX.COM
OBXC 05-2010
8
05-2010 Edition
Revision -
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
MODEL
RB
WEIR GATES
INSTALLATION: ROUND MANHOLE MOUNTED
Follow the instructions of “Concrete Wall Mounted” installation. Anchor bolts shall be installed per-
pendicular to the surface.
INSTALLATION: WALL THIMBLE MOUNTED
Required Materials:
Orbinox Wall Thimble Mounted RB Weir Gates are installed by means of Hex Bolts. In order to avoid
leakage between the wall thimble and the frame, construction sealant shall be used. (Sikabond Con-
struction Sealant or equivalent, 200ml per meter of opening perimeter). For detailed information
about the size and quantity of the required bolts, or any other specific installation notes or materials,
please refer to the notes on the „General Arrangement Drawing‟. Note that as standard, bolts and
construction sealant are not supplied with the slide gate.
Installation:
The concrete construction shall be flat, level and plumb, and shall be in accordance to ACI
117-06 standard.
If necessary, use non-shrink grout in order to meet the specified standard.
Apply construction sealant all around the perimeter of the frame. Sikabond (200 ml/m) or
equivalent construction sealant shall be used.
Partially tighten the four corner bolts, and check that the weir gate is perfectly lined up with the
wall thimble opening.
Install the rest of the bolts, and evenly tighten all of them.