INSTRUCTIONS FOR USE OMX 100
4.2.1.3.10 SELECTION OF AUTOMATIC MENU PRESETTING
DC
PM
OHM
F
DEF
+
ENA.
DIS.
CHA.
SER.
OUT.
CL. T.
AUX.
CFG
KEY
INP.
M.P.S.
MOD
A. ST.
CH.S.
Menu presetting
ENA.
Enable
- depending on the set input the following items
will be preset automatically:
- CHANNELS: MIN/MAX, FOR, DES
- OUT: A.O. > MIN/MAX
- aut. preset items will disappear from the menu
and reappear again after setting „MAN“
- example for input 4-20mA (PM):
MIN/MAX > 4-20; FOR > 00.0; DES > mA;
A.O. MIN/MAX > 4-20
DIS.
Disable
- as a standard, according to individual items
on the menu
4.2.1.4
SELECTION OF EXTERNAL INPUT FUNCTION
+
CHA.
SER.
OUT.
CL. T.
AUX.
CFG
KEY
INP.
LOC.
TAR.
HLD.
DEF
CL.C.
AU. 1
AU 1
Selection of external input
function
LOC.
LOCK, locking the control
keys on the instrument
HLD.
HOLD, stop measuring of
the entire instrument
TAR.
TARE - Tare* activation
CL.C.
Counter resetting
only for type „F“, mode
„COU“
4.2.1.5
SETTING ANOTHER FUNCTION OF THE CONTROL KEY „ENTER“
+
CHA.
SER.
OUT.
CL. T.
AUX.
CFG
KEY
INP.
ENB.
DIS.
DEF
ALL
ALL
Setting another function
of the control key
DIS.
Without function
ENB.
Activation of keys for Tare*
projection, in type „F“ in
mode „COU“ > resetting to zero
* only for type DC, PM, DU, F
When selecting „AUT.“ in type „F“ the decimal
point and description are preset in the range of
0,01 Hz…50,0 kHz. Limits and AO are set in kHz!