26
INSTRUCTIONS FOR USE OMX 100
4.2.3.3.2 ANALOG OUTPUT - RANGE
+
CHA.
SER.
OUT.
LIM
A. O.
DAT.
INP.
F. MI
TYP
F. MA
DIS.
MIN
MAX
A. O.
Setting the analog output
range
- analog output is isolated and its value
corresponds with the displayed data. It is fully
programmable, i.e. it allows to assign the AO
limit points to any two arbitrary points of the
entire measuring range
F. MI
Setting the beginning of the
frequency range for item
„MIN“
- range of the setting is 0,2…2 200 Hz
F. MA
Setting the end of the
frequency range for item
„MAX“
- range of the setting is 0,2…2 200 Hz
MIN
Assigning the display value
to the beginning of the AO
range
- range of the setting is -99…999
MAX
Assigning the display value
to the end of the AO range
- range of the setting is -99…999
4.2.3.4 DISPLAY
PROJECTION
+
CHA.
SER.
OUT.
LIM
A. O.
DAT.
INP.
1 s
MAX
OFF
DIS.
REF.
DIS.
Display projection mode
REF
Display refresh
MAX
Display value is changing at
maximum rate
- it burdens the processor performance, i.e.
in fully equipped transmitter the arithmetic
operation may be slowed down
1 s
Display value is being
restored 1x per second
OFF
Display is off
- after pressing the control key the display is
active after 60 s at max. projection rate