background image

Interrupting or Halting timer Output

The Timer has several built-in features that allow the user to 

momentarily interrupt or halt the electrical output to the station 

valves.
•  To momentarily interrupt the electrical output to the stations, 

press the off/auto resume button on the hand held wireless 

transmitter. This is useful for making a quick repair or pattern 

adjustment in the sprinkler system. To restart the electrical 

output, simply press the off/auto resume button once again. 

NOTE: The program will return where it would have, had the 

interruption not occurred. For instance, the Timer does not try 

to recapture any automatic watering which is lost due to the 

interruption.

•  To halt or discontinue semi-automatic or manual watering, 

press the clear key once.  The Timer will revert to your original 

automatic watering plan.

Using the User Selectable rain delay Mode

To stop automatic watering for 24, 48, or 72 hours, use the rain 

delay mode key.
•  With the rotary dial set to auto, press the rain delay key once.  

The Timer will force a 24-hour interruption of all scheduled 

watering.  After 24 hours, the Timer will automatically return to 

its initial watering schedule.

•  To increase the rain delay to 48 or 72 hours simply  press the 

rain delay key again until the desired delay time is displayed.

•  To cancel the rain delay mode, press clear [See Figure 15].
•  Note: While in rain delay mode, the timer will display the 

remaining hours (counting down) to the end of the accepted 

delay alternating with the current time and date. No other key 

besides clear is accepted while the Timer is in the rain delay 

mode. (Wireless operation is still possible)

figure 15:  display Showing rain delay

Complete System Shut down

To shut the system down, turn the rotary dial to the off 

position.  The Timer remains programmed but will not water.

Section five

USInG rEMOtE 

Setting up the Wireless features

The Wireless Remote features of the Timer allow you to operate 

the Timer from up to 200 feet away using the hand held Wireless 

Transmitter. You can turn on all stations or a specific station, 

for a number of minutes. This feature is especially helpful in 

troubleshooting, making adjustments and repairs, performing 

additional watering, and for start-up and shut-down of the 

sprinkler system.
•  First, install a 9-volt alkaline battery into the hand held 

Transmitter [see Figure 16]. To test the battery, press the off/

auto resume button on the Transmitter. The red light on the 

9

figure 12: Manual Watering in Either the A or b Program Only

 

Using Manual Operation

The manual operation mode allows you to set 

durations in any of the six stations from 1 to 99 minutes.
•  Turn the rotary dial to auto.
•  Press the manual key.  Then press next three times.  The display 

will show a blinking cursor on station 1 along with - - MINS [See 

Figure 13].

figure 13

•  To set the number of minutes for watering duration, press 

and hold the + key to advance to desired number of watering 

minutes.  Use the - key to go in reverse.  Press enter to begin 

watering.

•  To skip a station, press next until the cursor is blinking over 

the station number you wish to program.  Example:  To set 

station 3 for five minutes, press the manual key; then press 

the next key five times to select the manual operation mode 

and advance to watering for station 3; using the + or - key, set 

the manual watering duration to five minutes; then press enter 

[See Figure 14].

figure 14:  Manual Watering Station 3 for five Minutes

Note:  After the manual key has been pushed, if a selection is not 

made within 60 seconds the display returns to the time of day.

8

EnGLISH 

 

 

 

 

 

 

Summary of Contents for 57096

Page 1: ...ur Programmateurs pour systemes d arrosage par Orbit p 801 295 9820 f 801 951 5815 www fluid studio net 1065 South 500 West Bountiful Utah 84010 proof no 3 date 11 02 11 des MZ client Orbit sku 57096...

Page 2: ...Servicio t cnico 1 800 488 6156 or 801 299 5555 Aviso de marca registrada WaterMaster es marca registradas de la compa a Orbit Irrigation Products Inc table of Contents ENGLISH Section One Introducti...

Page 3: ...the factory installed fail safe program To prevent an accidental reset the button is recessed into the panel and must be pressed with a small pointed object such as a pen or pencil tip 2 Digital Displ...

Page 4: ...tinuously in successive weeks Program B Interval Odd Even Provides two options One for odd or even day watering or one for intervals ranging from everyday to every 28th day This feature is designed to...

Page 5: ...ds you can use either or both programs Enter the Watering Schedule in Any Order You have the option of entering your watering schedule in whatever order you like This feature makes it very easy to rev...

Page 6: ...omatic Operation Section Four Semi Automatic and Manual Operation The Orbit Timer has the ability to override the automatic program without disturbing the preset program Using the Semi Automatic Mode...

Page 7: ...lete System Shut Down To shut the system down turn the rotary dial to the off position The Timer remains programmed but will not water Section Five Using Remote Setting up the Wireless Features The Wi...

Page 8: ...ing Transmitter Battery To test the wireless system hold the Transmitter near the Timer the Timer must have the transformer installed and press the off auto resume button on the Transmitter If powered...

Page 9: ...gram coding is complete Section Six Installation Timer Location Select a location near a standard electrical outlet Avoid using an outlet controlled by an On Off switch The timer should not be exposed...

Page 10: ...Orbit Irrigation Products Inc 845 North Overland Rd North Salt Lake Utah 84054 www orbitonline com 15 Connecting the Transformer With the cover off find the two terminal holes labeled 24vac Make sure...

Page 11: ...miautom tica para dar flexibilidad de riego Usted puede anular la programaci n autom tica del Regulador en distintas maneras Secci n dos Para comenzar La programaci n del Regulador se puede lograr sig...

Page 12: ...ntrada Recuerde que cada hora de inicio activar todas las estaciones que se hayan programado para funcionar Cada estaci n no cuenta con horas de inicio distintas Las horas de inicio no corresponden a...

Page 13: ...or todo el programa sin temor a cambiar la programaci n Si usted desea cambiar las horas de inicio los d as de riego o los intervalos simplemente siga las instrucciones para ese programa Despu s de re...

Page 14: ...a que el cursor est intermitente sobre el n mero de estaci n que desee programar Por ejemplo para fijar la estaci n 3 por cinco minutos oprima la tecla manual luego oprima cinco veces la tecla siguien...

Page 15: ...per odo espec fico de riego usando el Transmisor inal mbrico Oprima el bot n de la estaci n deseada en el Transmisor n mero 1 2 3 etc El Transmisor emitir una sola se al ac stica y la luz roja se enc...

Page 16: ...imadamente 200 pies 60 metros Esta distancia se puede ver afectada por obst culos como paredes 27 Oprima el bot n encendido para el per odo deseado de riego seleccione los per odos de duraci n de 2 10...

Page 17: ...lugar tan alto como lo permita la conveniencia de operaci n y funcionamiento Montaje del Regulador Atornille un tornillo No 8 a nivel de la vista dejando la cabeza del tornillo salida de la pared apr...

Page 18: ...formador defectuoso o desconectado 2 Programaci n incorrecta 3 Se quem el fusible El Regulador no enciende 1 Se quem el fusible 2 Transformador no est enchufado en un tomacorriente que funciona V lvul...

Page 19: ...ela emp che le programmateur d enfreindre le programme d arrosage en jours pairs ou impairs Modes manuel et semi automatique Le programmateur vous offre un certain nombre de modes manuels et semi auto...

Page 20: ...aque station Les heures de d marrages ne correspondent pas des stations sp cifiques 35 Pour commencer La programmation du programmateur peut tre accomplie par une s rie de quelques tapes de base Avant...

Page 21: ...rogrammateur suive automatiquement votre programme 37 Figure 5 Affichage LCD avec heure de d marrage Dur e d arrosage pour le programme A ou B Note les deux programmes requi rent la programmation des...

Page 22: ...matique En mode automatique chaque programme fonctionne en s rie en commen ant par le programme A Figure 9 Pr t pour un fonctionnement automatique Section quatre Fonctionnements manuel et semi automat...

Page 23: ...uche manuel et ensuite appuyer sur la touche suivant cinq fois pour s lectionner le mode de fonctionnement manuel et avancer l arrosage pour la station 3 l aide des touches et r gler la dur e d arrosa...

Page 24: ...ou tre situ e dans un emplacement dont la temp rature peut 43 Fonctionnement du programmateur l aide du dispositif sans fil Le dispositif sans fil vous permet d effectuer des cycles d arrosages semi...

Page 25: ...la borne d sign s par 24VCA Veiller ce que le transformateur ne soit pas sous tension Ins rer l une des deux amen es de courant du transformateur dans chaque borne Mettre le transformateur sous tensi...

Page 26: ...stations est bloqu e et ne s arr te plus 1 Vanne d fectueuse 2 Particules de salet ou d bris coinc s dans la vanne 3 Diaphragme de la vanne d fectueux Toutes les vannes ne s ouvrent pas 1 Le transfor...

Page 27: ...tection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction...

Reviews: