2
INSTALLATION
The unit has a sensing angle of 360° and can detect
up to 5 meters radius at the mounting height of 2.2
meters or 7 meters radius at the mounting height of
5 meters. (FIGURE 3)
FIGURE 3
Wiring Instruction:
(1) Switch off the power source or wall switch.
(2) Strip approximately 6-8mm insulating part of the
power supply wire. Connect the power cord to
power supply wire using the wire nuts provided.
(3)
Study the following figure for wiring information
.
The power cords
of “LS” and “N” marks are to be
connected to the lighting fixture. (FIGURE 4)
Warning: Incorrect wiring could damage the
sensor or connected load, and also may cause
electrical harm.
FIGURE 4
(4) In order to install the sensor to the ceiling, drill a
diameter of 68mm round hole on the ceiling.
Wedge the main body into the round hole directly.
(FIGURE 5)
FIGURE 5
SETTING THE LIGHTING SYSTEM
(1) TEST MODE
Turn the Lux control and the Time control
counter-clockwise to the edge-the TEST position.
(FIGURE 6)
FIGURE 6