Installation Overview
Installation Requirements
Connectivity
Internet connection:
Either password protected 2,4 GHz / 5 GHz Wi-Fi network or
Ethernet is required.
Ethernet is a factory added option. It is not possible to use Wi-Fi as
connection method after the shower has been prepared for Ethernet.
Electrical Supply
Residual circuit breaker:
One breaker per Shower Core
Power supply:
One Phase, 240VAC / 50 Hz / 16A
Mains supply wire:
Min. 2.5 mm
2
(rated for 16A circuit)
Plumbing / Water
Incoming water supply connections:
Separate hot and cold, 2x female G 1/2" swivel nut
Incoming cold water temp. (min-max):
4-25°C
Incoming hot water temp. (min-max):
50-65°C
Incoming water pressure (min-max):
2-10 bar
The supply pressure is the fundamental requirement for the shower
flow:
• 2 bar: 7.5 litres/min
• 3 bar: 9.5 litres/min
• 4 bar: 11 litres/min
Recommended water supply flow:
9 litres/minute per inlet hot and cold
Water hardness (min-max):
Minimum: 3°dH-10°dH
Recommended: 6°dH-10°dH (or a total hardness of 110-180mg
CaCO
3
/litre)
Water iron content:
<0,3mg/litre
Page 7 of 33
Summary of Contents for OAS Standart R3
Page 1: ...Fixture Installation Orbital Shower Panel R3 5 06 0009 Publication date 2021 08 27 ...
Page 4: ...This page is intentionally left blank Page 4 of 33 ...
Page 9: ...2190 mm 575 mm 150 mm 1265 mm 230 mm 184 mm 145 mm mm 122 mm Page 9 of 33 ...
Page 18: ...1 100mm 2 3 Page 18 of 33 ...
Page 20: ...2 1 RSK 831 41 66 3 4 600mm Page 20 of 33 ...
Page 32: ...This page is intentionally left blank Page 32 of 33 ...
Page 33: ...C E R T I F I E D S P A C E T E C H N O L O G Y ...