[REV. 20190510] OC_GF_RA_BA_790142765_00__INH-02_EN
Orbitalum Tools GmbH
D-78224 Singen www.orbitalum.com
99
GF 4, GF 6, RA 8, RA 12 (AVM/MVM)
Servicing, maintenance, troubleshooting
enGLISH
10.1.1 Line laser
X
Own maintenance work on the laser is not permitted. The laser is to be returned to the factory for any maintenance or repair
work that may be required.
X
It is not allowed to open, modify or to remove protective covers or housings except for battery change.
10.2 checking the oil level of the gear and topping up
The gears of the pipe cutters have an oil level indicator.
The oil level should be visible in the middle of the inspection
glass.
1. Check the oil level through the inspection glass (2) and top
up if necessary.
2. To top up: Unscrew the oil filler screw (1). Fill with special
Orbitalum Tools gear oil.
3. Re-insert and tighten the oil filler screw.
10.3 cleaning the slide guide
WARnInG!
Danger of being injured by a not sufficiently secured slide!
X
never
dismount the slide by pulling it downwards.
X
Always tighten the safety screw when assembling the slide.
1. Remove the safety screw (1).
2.
Turn the slide housing upwards by 180°.
3. Turn the hand wheel (2) counterclockwise.
4. Pull out the slide (3) with the motor upwards.
5. Clean the guides of the slide housing and slide. Lightly lubricate both parts using HD 30 engine oil.
6. Remount the slide. Insert and tighten the safety screw (1).
1
1
3
2
180°
Position of the safety screw for the GF 4 and GF 6 (AVM/MVM).