Commissioning
ORBIMAT 180 SW
| Operating instructions
26
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
(17.09.18) OW_ORBIMAT_180SW_BA_850060202_00_EN
X
Ensure that the machine is
not
connected to the mains network during filling.
X
Secure the machine against being switched on unintentionally.
Please adhere to the following steps, otherwise the pump could be damaged by running dry:
7.5.1
Topping up coolant
1. Open the tank lid and fill ORBITALUM coolant OCL-30
(Code 850 030 010) carefully into the tank (2) until the
coolant level has reached the "MAX" marking on the
sight glass at the left-hand side panel of the power
source (3).
2
3
Use of other cooling units such as compressor cooling device, type ORBICOOL Active):
1. Fill in coolant in accordance with the operating instructions of the unit.
2. Connect the coolant hoses at the front connectors of the power source to ensure the coolant flow and temperature
monitoring by the power source.
7.5.2
Connecting Remote control/dummy plug
1. Connect the supplied dummy plug (4) or the optionally available remote control (5) (code 875 050 001) via the
adapter cable (6) (included in the scope of delivery of the remote control) to the remote control socket (7).
2. If a remote control is connected, the STOP button (8) must be unlocked as well.
3. The power source cannot be switched on without the dummy plug or unlocked remote control.
4
5
6
7
8