ORBIMAT 180 SW
| Operating instructions
Operation
(17.09.18) OW_ORBIMAT_180SW_BA_850060202_00_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
33
"Test mode" is indicated by the "Start" button having a yellow background.
The start command in test mode starts running a procedure without igniting an arc and therefore
without weld current; the gas valve and coolant pump are switched off. You can use this "dry run"
to check the change in level at the intended points on the pipe and the run of the motor.
Fig. 11:
Machine ready to start – Welding (left)
Fig. 12:
Machine ready to start – Test run (right) – Start
X
To change between the welding mode and the test mode the yellow "GAS" button at the weld head remote control
or at the handle of the weld head can be activated by pressing it and keeping it pressed for 3 seconds.
With the remote control of the weld head:
X
Press the gray "
Motor
" button until the desired position is reached. Only one rotation direction is possible here.
With an additional remote control (optional, available as accessory):
X
Press the "
MOTOR+
" or "
MOTOR –
" button.
The rotor turns in the selected direction as long as a button is being pressed.
With the push switches of the machine:
X
Call up main menu, if necessary.
X
Press softkey 2 "
Test
".
The main menu in test mode appears in the display, and the "
Start
" button is yellow.
X
Press softkey 4 "
Motor
".
The assignment of the softkeys for controlling the motor changes.
X
Press "
Motor forward
" or "
Motor backward
" button.
The motor runs in the selected direction as long as the button is being pressed.
X
Press softkey "
Home
".
The weld head turns to the open position.
X
Press softkey "
Motor OK
" to exit the operating scheme.
X
Press softkey 5 "
Menu
" to change directly to the main menu.