ORBIMAT 180 SW
| Operating instructions
Service and troubleshooting
(17.09.18) OW_ORBIMAT_180SW_BA_850060202_00_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
73
No.
Error message
Explanation/Elimination
18
An error has occurred!
Please contact our Support
Plain-text message which can appear with the "Error code" message (Message
17).
X
Contact Orbitalum if the problem cannot be solved.
19
Parameter error
20
Drive not found
21
File not found
22
Path not found
23
Folder full
24
Drive full
25
Drive not ready
26
Write protection
27
File access error
28
The name contains impermis-
sible characters
29
Procedure cannot be opened
under the name
30
The version of the file does
not match. The file has been
modified!
X
Reload/copy/correct file.
31
Further procedures cannot be
created!
For messages with "90%" specifications:
Resources almost used up. Additional data can still be saved.
Recommendation:
X
Clean up the system by deleting or externally saving data which are no longer
required.
The number of folders and procedures per folder is limited to 100, however.
32
Over 90% of resources for
procedures used up!
33
Additional folders cannot be
created!
34
Over 90% of resources for
folders used up!
35
The procedure cannot be
loaded!
Procedure cannot be loaded after switch-on.
When the machine is switched on, the last used program is loaded. It this not
possible, (because the USB stick has been removed, for example), the default
procedure is loaded.
X
Contact Orbitalum if the problem cannot be solved.
36
The procedure cannot be
saved!
A problem occurred while saving the procedures.
The error appears in "plain text" (see Messages 18 through 29) or as a two-digit
number.
37
File with inverter characteris-
tic cannot be opened!
Default values are used.
File with characteristics cannot be read. Current adjustment of the machine
ineffective.
A file generated during current adjustment is stored on the internal memory of
the machine: During calibration, a digital adjustment is carried out, where the
differences between the setpoint and actual values and the measured values of
a calibrated measuring unit can be recorded point by point and saved in a file.
If the file is not readable, the error coefficients are given the default value (= 1).
This makes the current adjustment carried out by Orbitalum ineffective.
X
For applications which entail data monitoring and actual value recording,
stop working with the machine.
X
Contact Orbitalum to restore the calibration data.
38
Auto programming failed!
The auto programming file
may be missing or corrupt.
Auto programming error.
Causes:
• The combination of pipe diameter and wall thickness lie outside the value
range of auto programming (for example wall thicknesses over 4 mm)
X
Use other parameters.
• Data of the database on the internal memory not present or not readable.
X
Contact Orbitalum to restore the data.