No.
Error message
Explanation/Elimination
39
External storage medium not
found!
Possibly no USB stick is
inserted in the USB port
Access to external USB stick not possible.
X
Check whether the USB stick is recognized by the system.
X
Remove the USB stick, wait briefly and insert it again. Possibly use a differ-
ent port.
X
Check whether the USB stick is defective or has an unreadable format.
X
Contact Orbitalum service if the problem cannot be resolved.
40
Error when saving log
Software conflicts due to damaged files or files with unreadable contents.
The message is followed by the error in "plain text" (see Messages 18 through
29) or as a two-digit number.
41
Procedure file cannot be
opened!
42
Log file cannot be opened!
43
Some currents are set too
high.
They cannot be achieved with
a 115 V mains voltage!
Machine connected to mains network of less than 200 V AC. The maximum weld
current is limited to 120 A. Procedure with higher weld current has been started.
44
An error occurred while read-
ing the file FAILURES.TXT!
Internal error log ("Failures.txt" file) is not present or is damaged.
45
No weld head connected!
Procedure started, no weld head connected to the machine.
Weld head connected?
• Weld head not encoded
• Voltage supply to weld head defective. The operating buttons in the weld
head are not working.
X
Contact the Orbitalum service.
46
Incorrect weld head con-
nected!
The currently connected weld head is not the same as the weld head in the
started procedure.
X
Select the connected weld head in the procedure.
– or –
X
Connect the weld head selected in the procedure to the machine.
Are the weld head models identical, but the message appears nevertheless?
X
Contact the Orbitalum service.
47
The procedure contains pa-
rameters that lie outside the
limit values for the selected
weld head!
Weld head changed in the procedure. Weld head does not match the param-
eters.
The weld head list of the machine contains the parameters of the weld heads
which can be connected to the machine, e.g. the maximum rotation of the rotor,
the maximum pipe diameter to be welded and the maximum permissible cur-
rent.
X
Adjust the parameters of the procedure to the selected weld head.
48
Motor current
>> Collision recognition
Norm. motor current
Motor current time
Transmission sluggish.
X
Check the head.
X
If necessary, repair the transmission.
49
Electrode replacement warn-
ing
X
Replace the electrode.
50
Calibration error/fault
("Calibration aborted due to
execution error"; "Calibration
aborted due to operational er-
ror"; "Calibration aborted due
to parameter")
X
Execute calibration again or restart the machine.
51
Error while copying proce-
dures or logs
X
Check whether write protection is active. The drive is possible not ready.
52
Printing error. Error during
communication with the
printer
X
Check the connection to the printer.
X
Check the network connection.
X
Refresh the printer list.
53
Settings incorrect
X
Check the entries.