ORBIMAT 180 SW
| Operating instructions
Service and troubleshooting
(17.09.18) OW_ORBIMAT_180SW_BA_850060202_00_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
75
No.
Error message
Explanation/Elimination
54
Shared folder could not be
created/connected
X
Check whether the shared folder is set to "
Public
".
X
Check whether the input data are correct.
X
Check whether the IP address range matches.
55
Touch screen could not be
changed
X
Restart the machine.
56
CAN timeout error
X
Acknowledge the message with "
Okay
".
If the welding process is not possible:
X
Contact the Orbitalum service.
57
Required current higher than
the maximum current of the
inverter
X
Check the current settings.
If this error message appears repeatedly:
X
Contact the Orbitalum service.
58
Weld held parameters for
wire are incorrect.
X
Check the wire settings.
9.4
Status LED indicators
There are three smaller LEDs lighting green or flashing on the rear of the machine:
1. Process (CPU alive)
2. Coolant pump on or off
3. Coolant flow
LED 1 does not light up
> Machine off
LED 2 does not light up
> Coolant pump off
LED 3 does not light up
> Coolant flow does not exist
9.5
Temporarily deactivating sensors and monitoring functions
9.5.1
Sensors
Certain sensors can be deactivated temporarily. This can make sense, for example, when a defective gas sensor is present
and work is to continue. Greater attention is required when continuing work with the machine.
The sensors cannot be deactivated permanently:
Deactivation of the sensors for gas and coolant monitoring is reset
each time the machine is switched off. The sensor is active again after the machine is started again.
9.5.2
Monitoring limits
The application of the monitoring limits can also be deactivated.
9.5.3
External input for aborting
If an external device with abort function is connected (for example residual oxygen meter), the function must be acti-
vated so that the abort signal is processed by the unit in the machine.
If an external device is not connected, the function must be deactivated.
X
When deactivating sensors and monitoring limits, be aware that the corresponding monitoring function is no longer
active.
Example: With the gas sensor deactivated, the welding process is no longer interrupted if the gas bottle is empty.
X
Deactivate sensors only in cases where this is absolutely necessary.