8 What to do if ...?
Operating instructions SCORP
22
(06.07)
MT_SCORP_BA_04_790014762_09.doc
orbitalum tools
gmbh
8
What to do if ...?
8.1 Problem
solving
In the following table you will find possible causes for faults and the appropriate
remedies.
Fault Possible
cause
Remedy
The engine does not run.
Current supply interrupted.
Examine the inlet cable.
When the blade is dull or the
speed is too high, the overload
protection cuts power
automatically.
Restore the power by pushing the
overload protection switch
(switch for overload protection,
see chapter 2.1, p. 6).
SCORP is not turnable.
Pipe clamp too strong fixed.
Loosen the pipe clamp by
adjusting the regulating knob until
the SCORP is turnable.
Pipe clamp cannot be opened
and/or closed.
Too high contamination.
Clean and/or lubricate the
SCORP.
Abrasion.
Contact the service station
(see chapter 8.2).
Moveable protection housing is
jammed.
Too high contamination.
Clean and/or lubricate the
SCORP.
Abrasion.
Contact the service station
(see chapter 8.2).
Release button is locked or
cannot be locked.
Too high contamination.
Clean and/or lubricate the
SCORP.
Release button defect.
Contact the service station
(see chapter 8.2).
8.2 Servicing/customer
service
For ordering spare parts, see the separate spare parts list.
For problem solving, please contact your competent branch office directly.
Please give the following details:
•
Machine
type:
SCORP 220 Plus
or
SCORP 360
•
Machine
number:
(see the identification plate)