DP-100SL
5
Site Preparation Guide
The imager unit should be located in a room that can be closed off
during periodic maintenance and repair
. At the user level, the imager
is a Class 1 laser device (no special protection needed) during all standard
operations. However, during certain service procedures, Class 4 will be
reached, and therefore a warning light must be installed (see
).
Main Wavelength
355nm
(350-360nm UV light)
quasi-cw power of 10W
Secondary Wavelengths:
1064nm
(1060-1070nm UV light)
quasi-cw power less 0.2W
532nm
(520-540nm green light)
quasi-cw power less 0.2W
Minimal Beam Diameter
0.05 mm
Minimal Beam Divergence
0.5°
Pulse Rate
80MHz
Pulse Energy
125nJ
Pulse Length
5 … 20 ps
Max Power
10 W
Note
A class 2 measuring sensor (wavelength 660nm) is also used.