DP-100SL
15
Site Preparation Guide
Height Requirements
Height of the system with the hood raised is 2689 mm (105.8"). We
recommend a ceiling height of at least 2800 mm (110.2").
During installation, the machine height may vary within a vertical range
of approx. 80 mm (3.15"). Achievable height levels are:
• Between 964 mm (37.9") and 1044 mm (41.1") for the machine table.
• Between 1021 mm (40.2") and 1101 mm (43.4") for the upper edge of
the machine shielding (mouse and keyboard placement level).
Figure 3.1 External Warning Light
Supply
Relay
24 V AC
DP-100SL
Laser
Warning
Lamp
Max 500mA