User manual
FLEXI 50
33
10
MAINTENANCE
Fan maintenance consists of regular cleaning of dusty surfaces and cleaning or replacement of filters. Follow
these steps to access the main service units:
Remove the inner cover front panel, disconnect the connector, and pull the cable to remove the cartridge
from the air tube. Remove the filters from the cartridge.
Clean the filters according to the degree of clogging, but at least once every three months.
•
When the filter timer countdown (90 days) is completed, the filter replacement indicator
appears on the control panel.
•
Wash the filters and allow them to dry completely. Insert the dry filters back into the air duct.
•
Vacuum cleaning is allowed.
•
To reset the filter servicing timer, press and hold the button
for 4-5 s.
•
The rated life of the filter is 3 years.
•
Contact the seller for new filters to the ventilator
Replacement indicator
Disconect the unit from power supply before any maintenance operations!