background image

2

Fitting and maintenance instructions HRC 300/400 4B(P/RH)

1. 

General 

2

2. 

Version 

3

2.1   General 

3

2.2   Fitting HRC in brief 

3

3. 

Installation 

4

3.1 

Mounting frame 

4

3.2  Important Instruction 

 4

3.3  Connecting ducts 

4

3.4  Connecting condensate discharge 

5

3.5  Placing the heat recovery module 

6

3.6  Replacing the cover 

6

3.7 

Electrical connections 

 6

3.7.1  HRC with 4 core and earth cable 

6

3.7.2  HRC with wireless remote control 

6

3.7.3   Speed control with 4 core and earth cable  

(BP model only) 

6

3.7.4   Speed control with a wireless remote control 

(BRH model only) 

6

3.8  Overview connection HRC 

7

3.9  Adjusting the air performance 

7

4. 

Maintenance 

10

4.1 

User maintenance 

10

4.2  Installer maintenance 

11

4.3   Mounting of the heat-exchanger and the motor plates  12
4.4  LED indication / Fault warnings 

12

5. 

Technical specifications 

13

5.1 

Wiring diagram Orcon HRC 300/400 4B(P/RH) 

13

5.2  Appliance data HRC 300 4B(P/RH) 

14

5.3  Fan graph HRC 300 4B(P/RH) 

15

5.4  Appliance data HRC 400 4B(P/RH) 

16

5.5  Fan graph HRC 400 4B(P/RH) 

17

5.6  Setting transmitter / receiver (RH model only) 

18

6. 

Maintenance 

19

6.1 

Exploded view HRC 

19

 

Declaration of conformity 

19

To maintain a healthy indoor environment closely-controlled 
ventilation is essential. There are many pollutants that will 
affect the indoor air quality: human body waste products 
in shape of CO2, dead skin, perspiration and moisture. 
Add to this the waste product of cooking (cooking-smells), 
showering (moisture), gases from building-materials and 
the waste products of pets.
Without proper ventilation this environment would be perfect 
for the growth of mould and subsequently damage to the 
decoration and fabric of a dwelling.

The HRC unit is fitted with two fans: The exhaust fan ensures 
that warm damp and polluted air as near as possible to 
the source will be extracted. The exhausted air must be 
replaced with fresh air and so the HRC heat recovery unit 
has not only an exhaust fan but is also fitted with a supply 
fan and air filters.
The supply air, which in winter is colder than the inside air, is 
heated in the heat recovery unit using the heat of the exhaust 
air by means of the heat-exchanger. This heat exchanger 
has an efficiency of 97%, so a minimum loss of heat takes 
place and the supply air temperature is at an acceptable 
and comfortable level.

In the summer, when heat-recovery is not desirable, the air 
does not go through the heat exchanger, but is diverted by 
way of a bypass-valve. By doing this during the night, with 
relatively cool supply air to ventilate the dwelling, a cooler 
dwelling temperature is possible. This is automatically 
detected and controlled by the unit electronics. 
The electronics also ensures, that in winter, when ice-formation 
in the exchanger is possible, the exchanger is defrosted, at a 
time that is most comfortable to occupants of the dwelling.
Further the fan speed will automatically switch up to a 
higher setting when a 5% increase in relative humidity is 
detected within a 2 minute period (usually during showering 
or cooking). After a preset period the unit will return to the 
lower set speed. The fans are energy-low by the use of EC-
motors with a constant (adjustable) air volume.

The filters in the unit ensure that the fresh supply air is clean 
as it enters the dwelling. Also the extract air from the property 
is filtered, so that the pollution of the heat exchanger is 
minimised. 
These filters have to be cleaned every month, depending 
on the pollution. The electronics in the unit is fitted with a 
timer for filter cleaning which automatically indicates when 
it is time to clean the filters. The maximum period between 
replacements of the filters will be a year. 

Contents

1. General

Summary of Contents for HRC 300 4B P

Page 1: ...overy unit www orcon nl Type HRC 300 400 4B P RH Store near the appliance This manual is intended for users and installers of type HRC 300 400 B P RH This manual contains impor tant about the operatio...

Page 2: ...arm damp and polluted air as near as possible to the source will be extracted The exhausted air must be replaced with fresh air and so the HRC heat recovery unit has not only an exhaust fan but is als...

Page 3: ...rom the house are attached to the other side of the unit Also the condensate discharge under the unit can be fitted at this stage B When the ducting runs are completed if an appropriate electrical sup...

Page 4: ...ere to fit the condensate discharge The position of the electrical power supply an earthed wall socket or fused switched spur is also indicated The unit must be secured horizontally Ensure sufficient...

Page 5: ...void in such a manner as to prevent condensation in addition the discharge duct between the HRC and the roof terminal must be designed to prevent surface condensation The mechanical ventilation outlet...

Page 6: ...the upper side of the cover at the upper side of the mounting frame with the two screws provided If it is difficult to push the cover totally against the unit open the flap in the cover After closing...

Page 7: ...the turn module are used to configure the unit for left or right handed operation and must not be changed or removed after the initial set up Attention Keep the magnet away from creditcards and other...

Page 8: ...7 OFF 8 ON 280 m3 h 5 OFF 6 ON 7 ON 8 ON 300 m3 h 5 ON 6 ON 7 OFF 8 ON 300 m3 h 1 ON 2 ON 100 m3 h 5 ON 6 OFF 7 OFF 8 OFF 210 m3 h 5 OFF 6 OFF 7 ON 8 OFF 225 m3 h 5 ON 6 ON 7 OFF 8 OFF 240 m3 h 5 OFF...

Page 9: ...OFF 6 ON 7 OFF 8 ON 345 m3 h 5 OFF 6 ON 7 ON 8 ON 370 m3 h 5 ON 6 ON 7 OFF 8 ON 390 m3 h 1 ON 2 ON 120 m3 h 5 ON 6 OFF 7 OFF 8 OFF 255 m3 h 5 OFF 6 OFF 7 ON 8 OFF 275 m3 h 5 ON 6 ON 7 OFF 8 OFF 295 m3...

Page 10: ...ll start flashing on off This filter indication will start flashing each month The unit should not be used without filters Cleaning the filters by user 4 Maintenance 4 After cleaning replace filters a...

Page 11: ...an the fan with a dry stiff brush Prevent damage to the fan blades Do not use water for cleaning 2 Clean the heat exchanger with warm water and a mild detergent Rinse with warm water 1 Switch off the...

Page 12: ...of the unit Reconnect the power to the unit and check that the unit functions correctly 4 4 LED indication Fault warnings When there is a failure or a certain scenario this will be shown on the displa...

Page 13: ...13 Fitting and maintenance instructions HRC 300 400 4B P RH 5 1 Wiring diagram Orcon HRC 300 400 4B P RH 5 Technical specifications...

Page 14: ...ternal diameter condensate discharge mm 20 Filter class G3 F7 optional Weight kg 39 kg frame 12 kg unit 23 kg cover 4 kg Supply voltage V Hz 230 50 Protection degree IP30 Temperature efficiency 95 Fac...

Page 15: ...150 56 230 0 120 0 625 17 3 G 200 44 230 0 188 0 643 27 8 H 200 64 230 0 191 0 642 28 2 I 200 100 230 0 225 0 652 33 7 J 250 69 230 0 287 0 663 43 8 K 250 100 230 0 323 0 668 49 6 L 250 156 230 0 402...

Page 16: ...m 210 Outside diameter ducts External diameter condensate discharge mm 20 Filter class G3 F7 optional Weight kg 39 kg frame 12 kg unit 23 kg cover 4 kg Supply voltage V Hz 230 50 Protection degree IP3...

Page 17: ...230 0 223 0 549 28 I 200 100 230 0 262 0 559 34 J 250 69 230 0 334 0 570 44 K 250 100 230 0 375 0 575 50 L 250 156 230 0 467 0 574 62 M 300 100 230 0 548 0 578 73 N 300 144 230 0 600 0 565 78 O 300 22...

Page 18: ...receiver print continuously until the red LED goes After releasing the button the red LED on the receiver print will flash 5x The link with the remote is now erased Battery replacement When the LED in...

Page 19: ...1 Profile 12 Bypass 13 Cover Article codes service articles HRC Nr Article description Article code S1 Central PCB Orcon 3 1 22905024 S2 Receiver pcb RH model only 29190742 S3 Filter set 2 x G3 filter...

Page 20: ...Storkstraat 23 3905 KX Veenendaal NL P o box 416 3900 AK Veenendaal t 31 0 318 54 47 00 f 31 0 318 54 47 06 info orcon nl Orcon bv www orcon nl Edition april 2010 29199185 orc10018...

Reviews: