43
Fast charging is not appropriate for charging a battery which has been dead for a long
time. If fast charging is necessary, make sure to charge less than the current rated
capacity of the battery.
5) After auxiliary charging, return the 6 vent plugs to their original locations.
■Estimation of the auxiliary charge completion (meet the following conditions):
1 Electrolyte specific gravity is over 1.270 / 68 °F (20 °C) and continues for more than one
hour at a constant level.
2 Terminal voltage is over 15V and continues for more than one hour at a constant level.
3 The gas is generated from each cell.
4 The charging time is reached.
Installation Procedures:
1) Make sure there are no foreign objects on the mounted battery unit. Place the new
battery in with the mounts corresponding to the cables. Fasten the battery with the
mounting bracket.
2) Connect the + cable terminal to the + battery terminal*, and tighten the bolt firmly.
3) Then, connect the – cable terminal to the – battery terminal, and tighten the bolt firmly.
4) Greasing the inner sections of the cable terminal’s metal parts will help prevent rust.
*If the cable terminal is corroded, clean it with a wire brush or sand paper.
Starting:
After installing the battery unit in the machine, start the engine. Engine should start within 5
seconds, if it does not start, wait for more than 10 seconds and try it again. If it still does not
start, the battery life may be low; please check the starting circuit and battery.
Battery Life:
While the battery is in use, its capacity decreases gradually, and it will eventually run out.
If the battery does not re-charge when you do an auxiliary charge, replace with a new battery
A battery’s life is shortened by the following factors:
High temperature
Frequent use (it is affected by either to little or too much use).
Insufficient charging (the use of too many accessories can cause shortage due to the
failure of the generator).
Harsh use (high frequency of use in cold weather or use after insufficient charging).
Insufficient maintenance including: insufficient battery fluid level inspection and
rehydration, connection failure due to loosening of the terminal parts, uplifting of the
battery due to leaving the engine on when charging.
Overcharging caused by regulator failure. Continuing to charge after the charge is
complete.
At the end of battery’s life the following signs occur:
The rotation noise of the starter motor is lower and weaker than usual.
Fast decrease of the electrolytes of the battery.
When these signs appear, please do the auxiliary charging. If it still does not work well, please
replace the battery. Please follow local laws and regulations for disposing of old batteries.
Battery Type --
-U1R type, 12V 270CCA or greater