background image

GB

1

CABLE FREE WEATHER STATION

WITH 3 REMOTE SENSORS

MODEL: BAA968HG

USER’S MANUAL

INTRODUCTION

Congratulations on your purchasing of BAA968HG Top Weather
Station.

BAA968HG is an all-in-one clock and weather device. It forecasts
the weather with kinetic-moving graphic illustrations and gives
indoor and outdoor temperature. It also shows a trend indicator and
records minimum and maximum temperatures.

Apart from temperature, BAA968HG shows the indoor and outdoor
relative humidity and rates the comfort level. It also retains the
maximum and minimum relative humidity readings. 3 remote
thermo-hygro sensors are included with the unit. BAA968HG is
able to receive and display readings from up to 3 remote sensors.

The built-in barometer enables BAA968HG to display the atmos-
pheric pressure with user-selectable altitude adjustment. A bar
graph will show the pressure trend of the last 24 hours.

What is more, BAA968HG is equipped with a moon phase scanner,
which lets you check the moon phase of any day between 1990 and
2089.

Other features include a HiGlo backlight, daily crescendo alarm
with eight-minute snooze function, and extra-large display.

No wire installation is required between the main and remote units
as BAA968HG operates at 433MHz.

MAIN FEATURES: MAIN UNIT

A TABLE  AND  CONTROL  STAND

Acts as control panel and supports the unit when lying flat

B

SNOOZE / LIGHT  BUTTON
Activates the snooze function when an alarm goes off or turn
on the backlight for five seconds

C CLOCK  WINDOW

Displays the current time and date

D ALARM  ON  ICON

Appears when the alarm is activated

E

ALARM  ICON
Appears when the alarm time is displayed

F

MAIN  UNIT  BATTERY  LOW  (BATT)  INDICATOR
Lights up and blinks when the batteries of the main unit are
running dry

G REMOTE  UNIT  BATTERY  LOW  (BATT)  INDICATOR

Lights up when the batteries of the remote unit are running
dry

H WEATHER  FORECAST  WINDOW

Displays the weather pattern

I

TEMPERATURE  WINDOW
Shows the current temperature or the maximum or minimum
recorded temperature

J

IN/OUT - REMOTE  INDICATOR
Indicates if the current reading is displayed as indoor or outdoor-
remote

K TEMPERATURE  TREND  ARROWS

Indicates the trend of temperature changes

L

°C/°F  SLIDE  SWITCH
Selects between Centigrade (°C) and Fahrenheit (°F) display

Summary of Contents for BAA968HG

Page 1: ...nd 2089 Other features include a HiGlo backlight daily crescendo alarm with eight minute snooze function and extra large display No wire installation is required between the main and remote units as BAA968HG operates at 433MHz MAIN FEATURES MAIN UNIT A TABLE AND CONTROL STAND Acts as control panel and supports the unit when lying flat B SNOOZE LIGHT BUTTON Activates the snooze function when an ala...

Page 2: ...2 panels A C UNLOCK BUTTON Press to release the lock MAIN FEATURES REMOTE UNIT MODEL THGR228N a Two lineLCD Displays the current temperature and humidity monitored by the remote unit b LED indicator Flashes when the remote unit transmits a reading c C F slide switch Selects between Centigrade C and Fahrenheit F d Channel slide switch Designates the remote unit Channel 1 Channel 2 or Channel 3 e RE...

Page 3: ...tton to select either If 12 hour clock format is selected the time will be displayed with the AM or PM indicator Press MODE The hour digits will flash Use the UP or DOWN buttons to enter the hours Holding down either button will increase or decrease the value rapidly Press MODE to go to the minutes Set the minutes like you set the hours Press MODE to confirm If changes are made during minute setti...

Page 4: ...ton is pressed the SNOOZE function will be triggered The alarm will stop and the bell icon blinks for about eight minutes before going off again PRE ALARM FUNCTION FOR CHANNEL 1 REMOTE SENSOR The alarm function also has a pre alarm feature which can alert the user before the preset alarm time when weather condition changes This pre alarm function applies to Channel 1 Remote Sensor only To enable t...

Page 5: ... icon will flash to indicate such change It will stop flashing when the pressure reading is recorded again The atmospheric pressure can be displayed in mb hPa or inHg The pressure unit is selected on the atmospheric pressure slide switch inside the battery compartment If you want to check the pressure history for a particular hour during the past 24 hours press the HISTORY button Each press on the...

Page 6: ... range 20 0 C to 60 0 C 4 0 F to 140 0 F Temperature resolution 0 1 C 0 2 F RF Transmission Frequency 433 MHz No of Remote unit up to 3 units RF Transmission Range Maximum 30 meters Temperature sensing cycle around 39 43 seconds Remote relative humidity 25 RH to 95 RH measurement range Resolution 1 RH Use the UP or DOWN button to locate the date you want to check The calendar will be day driven in...

Page 7: ...nts of this manual may not be reproduced without the permission of the manufacturer EC DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 01 and complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the following standard s has have been applied Efficient use of radio frequency spectrum Article ...