background image

GB

2

M RELATIVE  HUMIDITY  WINDOW

Displays the relative humidity

N COMFORT  INDICATOR

Indicates the comfort level

O ATMOSPHERIC  PRESSURE  CHART

Shows the atmospheric pressure trend chart of the last 24
hours

P

ATMOSPHERIC  PRESSURE  WINDOW
Displays the current atmospheric pressure

Q PRESSURE  HISTORY  INDICATOR

Indicates the pressure history of previous hours

R PRESSURE  UNIT  SLIDE  SWITCH

Selects between mb/hPa and inHg display

S

MOON  PHASE  SCANNER
Displays the current moon phase or that of the date checked

T

CHANNEL  BUTTON
Selects among indoor & channel 1, 2, 3 or to enter auto scan
mode

U MEMORY  BUTTON

Displays the maximum or minimum temperature and relative
humidity or erases the memory

V HISTORY  BUTTON

Selects the pressure history of previous hours

W UP (   ) AND  DOWN (   ) BUTTONS

Increases or decreases the value of a setting, scan the
moonphase status and toggle the alarm status

X ALARM   /   

   BUTTON

Displays the alarm time

Y MODE  BUTTON

Changes the display mode of the clock or triggers the clock
setting mode

Z

RESET  BUTTON
Resets the unit by returning all settings to their default
values

AA BATTERY  COMPARTMENT

Accommodates four UM3 or AA-size batteries

AB LOCK  SLIDE  BUTTON

Slide to the right to lock the 2 panels

AC UNLOCK  BUTTON

Press to release the lock

MAIN FEATURES: REMOTE UNIT

MODEL THGR228N

a

Two-line LCD
Displays the current temperature and humidity monitored by
the remote unit

b

LED indicator
Flashes when the remote unit transmits a reading

c

°C/°F slide switch
Selects between Centigrade (°C) and Fahrenheit (°F)

d

Channel slide switch
Designates the remote unit Channel 1, Channel 2 or
Channel 3

e

RESET
Returns all settings to default values

f

Battery compartment
Accommodates two AAA-size batteries

g

Battery door

h

Wall-mount holder
Supports the remote unit in wall-mounting

i

Removable table stand
For standing the remote unit on a flat surface

BEFORE YOU BEGIN

For best operation,

1. Insert batteries for remote units before doing so for the main

unit.

2.  Position the remote unit and main unit within effective trans-

mission range, which, in usual circumstances, is 30 meters.

Though the remote unit is weather proof, it should be placed away
from direct sunlight, rain or snow.

BATTERY AND CHANNEL

INSTALLATION: REMOTE UNIT

The remote thermo-hygro sensor unit uses two (2) UM-4 or “AAA”
size batteries.

Follow these steps to install / replace batteries:

1. Remove the screws on the battery compartment.

2. Select the channel number on the CHANNEL slide switch.

N.B.: Remember to assign different channel numbers (1, 2 or 3)

to the 3 remote sensors included.

3. Select the temperature display unit on the °C/°F slide switch.

Summary of Contents for BAA968HG

Page 1: ...nd 2089 Other features include a HiGlo backlight daily crescendo alarm with eight minute snooze function and extra large display No wire installation is required between the main and remote units as BAA968HG operates at 433MHz MAIN FEATURES MAIN UNIT A TABLE AND CONTROL STAND Acts as control panel and supports the unit when lying flat B SNOOZE LIGHT BUTTON Activates the snooze function when an ala...

Page 2: ...2 panels A C UNLOCK BUTTON Press to release the lock MAIN FEATURES REMOTE UNIT MODEL THGR228N a Two lineLCD Displays the current temperature and humidity monitored by the remote unit b LED indicator Flashes when the remote unit transmits a reading c C F slide switch Selects between Centigrade C and Fahrenheit F d Channel slide switch Designates the remote unit Channel 1 Channel 2 or Channel 3 e RE...

Page 3: ...tton to select either If 12 hour clock format is selected the time will be displayed with the AM or PM indicator Press MODE The hour digits will flash Use the UP or DOWN buttons to enter the hours Holding down either button will increase or decrease the value rapidly Press MODE to go to the minutes Set the minutes like you set the hours Press MODE to confirm If changes are made during minute setti...

Page 4: ...ton is pressed the SNOOZE function will be triggered The alarm will stop and the bell icon blinks for about eight minutes before going off again PRE ALARM FUNCTION FOR CHANNEL 1 REMOTE SENSOR The alarm function also has a pre alarm feature which can alert the user before the preset alarm time when weather condition changes This pre alarm function applies to Channel 1 Remote Sensor only To enable t...

Page 5: ... icon will flash to indicate such change It will stop flashing when the pressure reading is recorded again The atmospheric pressure can be displayed in mb hPa or inHg The pressure unit is selected on the atmospheric pressure slide switch inside the battery compartment If you want to check the pressure history for a particular hour during the past 24 hours press the HISTORY button Each press on the...

Page 6: ... range 20 0 C to 60 0 C 4 0 F to 140 0 F Temperature resolution 0 1 C 0 2 F RF Transmission Frequency 433 MHz No of Remote unit up to 3 units RF Transmission Range Maximum 30 meters Temperature sensing cycle around 39 43 seconds Remote relative humidity 25 RH to 95 RH measurement range Resolution 1 RH Use the UP or DOWN button to locate the date you want to check The calendar will be day driven in...

Page 7: ...nts of this manual may not be reproduced without the permission of the manufacturer EC DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 01 and complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the following standard s has have been applied Efficient use of radio frequency spectrum Article ...