background image

GB

5

WEATHER FORECAST

BAA968HG is capable of detecting atmospheric pressure changes,
and basing on the data collected, can predict the weather for the
forthcoming 12 to 24 hours. The effective range covers an area of 30
to 50 km.

sunny

partly cloudy

cloudy

rainy

snowy

NOTE:

1. The accuracy of a general pressure-based weather forecast is

about 70 to 75%, and therefore, cannot be held responsible
for any inconveniences so caused by an inaccurate one.

2. The weather forecast is meant for the next 12 to 24 hours. It may

not necessarily reflect the current situation.

3. The “Sunny” icon, when applies to night time, implies clear

weather.

COMFORT LEVEL INDICATORS

The comfort level indicators COM, WET or DRY will tell you if the
curent environment is comfortable, too wet or too dry.

The comfort indicators will appear on the display of the main unit
when the following conditions are satisfied:

HOW TO CHECK

THE BAROMETRIC PRESSURE

The current and historical barometric pressure is shown on the
atmospheric pressure window.

For users staying at a higher altitude such as in the mountain area,
sea-level barometric pressure applies.  In this case, press and hold
HISTORY button to enter the altitude compensation setting mode.
Use the UP or DOWN button to select from –100 to 2500 meters
(whichever appropriate).  Press HISTORY button to confirm and
exit. If the altitude changes, the “ALT” icon will flash to indicate
such change. It will stop flashing when the pressure reading is
recorded again.

The atmospheric pressure can be displayed in mb/hPa or inHg.  The
pressure unit is selected on the atmospheric pressure slide switch
inside the battery compartment.

If you want to check the pressure history for a particular hour
during the past 24 hours, press the HISTORY button.  Each press
on the button will go back by an hour.

The recorded atmospheric changes for the past 24 hours are
displayed in a bar chart above the atmospheric pressure window.

HOW TO USE AND SCAN

THE MOON PHASE

BAA968HG is equipped with a moon phase display and scanner
with which eight moon phases are displayed on the screen  from
new moon to waning crescent. The one falls on the current day will
flash on the screen.

If it is a full moon or new moon day, the icon will flash faster.

The eight phases are:

To check the moon phase for a particular day, press the UP  or
DOWN  button once. The clock will enter moon phase scanning
mode.

Arrow

indicator

Humidity

Trend

Steady

Falling

Rising

Indicator

displays

on the unit

Temperature

Range

20°C to 25°C

(68°F to 77°F)

-5°C -+ 50°C

(23°F - 122°F)

-5°C -+ 50°C

(23°F - 122°F)

Humidity

Range

40%RH-
70%RH

OVER-
70%RH

 Below
40%RH

Shows that the

Current

Environment

Ideal range for
both relative
humidity and
temperature

Contains excess
moisture

Contains
inadequate
moisture

No

Indicator

Less than

20°C( 68°F) or

More than

25°C (77°F)

40%RH
     to
70%RH

No comment

New Moon

Waxing Crescent

First Quarter

Waxing Gibbous

Waning Crescent

Last Quarter

Waning Gibbous

Full Moon

Summary of Contents for BAA968HG

Page 1: ...nd 2089 Other features include a HiGlo backlight daily crescendo alarm with eight minute snooze function and extra large display No wire installation is required between the main and remote units as BAA968HG operates at 433MHz MAIN FEATURES MAIN UNIT A TABLE AND CONTROL STAND Acts as control panel and supports the unit when lying flat B SNOOZE LIGHT BUTTON Activates the snooze function when an ala...

Page 2: ...2 panels A C UNLOCK BUTTON Press to release the lock MAIN FEATURES REMOTE UNIT MODEL THGR228N a Two lineLCD Displays the current temperature and humidity monitored by the remote unit b LED indicator Flashes when the remote unit transmits a reading c C F slide switch Selects between Centigrade C and Fahrenheit F d Channel slide switch Designates the remote unit Channel 1 Channel 2 or Channel 3 e RE...

Page 3: ...tton to select either If 12 hour clock format is selected the time will be displayed with the AM or PM indicator Press MODE The hour digits will flash Use the UP or DOWN buttons to enter the hours Holding down either button will increase or decrease the value rapidly Press MODE to go to the minutes Set the minutes like you set the hours Press MODE to confirm If changes are made during minute setti...

Page 4: ...ton is pressed the SNOOZE function will be triggered The alarm will stop and the bell icon blinks for about eight minutes before going off again PRE ALARM FUNCTION FOR CHANNEL 1 REMOTE SENSOR The alarm function also has a pre alarm feature which can alert the user before the preset alarm time when weather condition changes This pre alarm function applies to Channel 1 Remote Sensor only To enable t...

Page 5: ... icon will flash to indicate such change It will stop flashing when the pressure reading is recorded again The atmospheric pressure can be displayed in mb hPa or inHg The pressure unit is selected on the atmospheric pressure slide switch inside the battery compartment If you want to check the pressure history for a particular hour during the past 24 hours press the HISTORY button Each press on the...

Page 6: ... range 20 0 C to 60 0 C 4 0 F to 140 0 F Temperature resolution 0 1 C 0 2 F RF Transmission Frequency 433 MHz No of Remote unit up to 3 units RF Transmission Range Maximum 30 meters Temperature sensing cycle around 39 43 seconds Remote relative humidity 25 RH to 95 RH measurement range Resolution 1 RH Use the UP or DOWN button to locate the date you want to check The calendar will be day driven in...

Page 7: ...nts of this manual may not be reproduced without the permission of the manufacturer EC DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 01 and complies with the essential requirements of Article 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the following standard s has have been applied Efficient use of radio frequency spectrum Article ...