If you wish to disable the auto-reception feature, press the [

]

button for three seconds. The radio reception signal [ ]  will

disappear. The unit will not respond to radio signals.

To enable the feature again, press the [

] button for three seconds.

The radio reception signal [ ] will start blinking to initiate

reception automatically.

HOW TO SET THE CLOCK MANUALLY

To set the clock manually, hold [MODE/SET] for three seconds. The
hour digits will blink.

Press [

] or [

] select the hour. Keep pressing the button to

increase or decrease the value rapidly.

Press [MODE/SET] to confirm. The minute digits will blink.

Repeat the same procedure to set the minutes, hour, current date,
month, display language, day-of-week and offset for the alternate
time zone.

Note: The time and date are displayed in 24-HOUR clock format.
For the language display, you can choose among English (E), German
(D), French (F) and Italian (I). Day-of-week is in the usual sequence
of Monday through Sunday.

For the alternate time zone, which is indicated by the ZONE icon,

enter the hour offset using the [

] and [

] buttons and the

BAR112HG will calculate the second time accordingly.

If there is an item you do not wish to change, simply press [MODE/
SET]
 to bypass the item.

When you are done, press [MODE/SET] to exit. The display will
return to the mode last chosen.

HOW TO SET AND ARM THE ALARMS

The BAR112HG has two alarms, ALARM 1 and ALARM 2. They
can be invoked together or independently.

To set an alarm:

1.

Press [

] once to select ALARM 1 or again to select ALARM

2

 

the last selected time of the alarm will be displayed. If you have

never set the alarm before, the time will be displayed as 0:00.

2. Press  [

] for three seconds. The hour digits will blink.

3. Enter the hour using [

] and [

].

4. Press  [

]. The minute digits will blink.

5. Enter the minutes using [

] and [

].

6. Press  [

] to exit. The 

 ] icon for the alarm chosen will be

displayed indicating the alarm set above is now armed.

You can also arm or disarm an alarm by pressing the [AL ON/OFF]
button.

When an alarm is armed, it will go off at the set time.

The four-step crescendo function allows the alarm to start off gently
and step up its intensity every 20 seconds for four times. Without
interruption, the alarm will go off for a total of two minutes. If no key
is pressed to turn off the alarm within these 2 minutes, the alarm will
go off again after 8 minutes.

If a second alarm goes off when the first alarm is sounding off, the first
alarm will be disabled automatically.

Summary of Contents for BAR112HG

Page 1: ...ion device this unit has a large four line liquid crystal display LCD for displaying weather forecast information in outdoor temperatures relative humidity a radio frequency RF controlled calendar clock time zone adjusted time and dual daily alarms Also the main unit can support up to three remote sensors Other features include a day of the week display in four abbreviated languages a four step cr...

Page 2: ...mote sensor channel H 1 2 ALARM ICONS Appears when the alarm time is displayed I 1 2 ALARM ON ICONS Appears when the alarm is activated J WALL MOUNT HOLE For mounting the unit on a wall TEMPERATURE RELATIVE HUMIDITY ALARM K AL ON OFF BUTTON TEMP RH ALARM ON OFF Enables disables HI LO temp alarm and HI LO RH alarm L HI LO BUTTON Set the upper or lower temperature alarm limits of individual channels...

Page 3: ... E RESET Returns all settings to default values F BATTERY COMPARTMENT Accommodates two AAA size batteries G BATTERY DOOR H WALL MOUNT HOLDER Supports the remote unit in wall mounting I REMOVABLE TABLE STAND For standing the remote unit on a flat surface BEFORE YOU BEGIN For best operation 1 Assign different channels to different remote units 2 Insert batteries for remote units before doing so for ...

Page 4: ...s 3 Replace the battery compartment door BATTERY AND CHANNEL INSTALLATION REMOTEUNIT The remote thermo hygro sensor unit uses two 2 UM 4 or AAA size alkaline batteries Follow these steps to install replace batteries 1 Remove the screws on the battery compartment 2 Select the channel number on the CHANNEL slide switch 3 Select the temperature display unit on the C F slide switch 4 Insert the batter...

Page 5: ...e unit in place Main unit Wall mount Table Stand Remote unit Wall mount Table Stand THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning Use a blunt stylus to hold down the button All settings will return to their default values GETTING STARTED Once batteries are placed in a given remote sensor unit it will start transmitting information at 4...

Page 6: ...ntil a dot is displayed in the box under the kinetic wave To display temperature humidity readings from a remote sensor Press CHANNEL until the appropriate remote sensor channel is displayed in the box under the kinetic wave If no readings are received form one particular channel for more than 15 minutes blanks will be displayed until further readings are successfully searched Check the remote sen...

Page 7: ...e set to automatically scan and display readings from the remote sensors and indoor readings When the remote sensor mode is active the display will show the readings from one channel for about 4 second and then proceed to the next channel display To activate the remote sensor scanning mode Press and hold CHANNEL for 2 seconds To deactivate the remote sensor scanning mode Press either CHANNEL MEM H...

Page 8: ...r percentage Press and hold the button for a rapid scrolling sequence by increments of five Note The temperature range is from 50 C 58 F to 70 C 158 F If this is the first time you set the limits the lower limit will start from 50 C 58 F and the upper limit 70 C 158 F Other wise the reading will start from the temperature last selected The humidity range is from 2 to 98 If this is the first time y...

Page 9: ... Shorten the distance when necessary TRANSMISSION COLLISION Signals from other household devices such as door bells home security systems and entry controls may interfere with those of this product and cause temporarily reception failure This is normal and does not affect the general performance of the product The transmission and reception of temperature readings will resume once the interference...

Page 10: ...button is pressed ABOUT RADIO RECEPTION The BAR112HG is designed to automatically synchronize its calendar clock once it is brought within range of the Frankfurt DCF77 radio signal When the BAR112HG is within range its radio control mechanism will override all manual settings When the unit is receiving radio signal the RADIO RECEPTION signal will start to blink A complete reception generally takes...

Page 11: ...y If there is an item you do not wish to change simply press MODE SET to bypass the item When you are done press MODE SET to exit The display will return to the mode last chosen HOW TO SET AND ARM THE ALARMS The BAR112HG has two alarms ALARM 1 and ALARM 2 They can be invoked together or independently To set an alarm 1 Press once to select ALARM 1 or again to select ALARM 2 the last selected time o...

Page 12: ... function properly each remote sensor must be set to different channels MAINTENANCE When handled properly this unit is engineered to give you years of satisfactory service Here are a few product care instructions 1 Do not immerse the unit in water If the unit comes in contact with water dry it immediately with a soft lint free cloth 2 Do not clean the unit with abrasive or corrosive materials Abra...

Page 13: ... operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the...

Page 14: ...lays shown in this manual may differ from the actual display The manufacturer and its suppliers held no responsibility to you or any other person for any damage expenses lost profits or any other claim arise by using this product The contents of this manual may not be reproduced without the permission of the manufacturer ...

Reviews: