background image

 

 20

EN

 TROUBLESHOOTING

Check here before contacting our customer service
department.

Problem

Symptom

Remedy

Baro

Strange

Set altitude / unit

reading

(

13)

Calendar

Strange date

Change

/ month

language(

11)

Problem

Symptom

Remedy

Clock

Cannot

1. Adjust.

auto-synch

batteries.

2. Press RESET

(

 18).

3. Manually

activate auto-
synch (

 11).

Remote

Cannot locate

Check batteries

unit

remote unit

(

 8)

Temp

Shows “LLL”

Temperature is

or “HHH”

out-of-range.

Clock

Cannot

Disable auto-

change clock

synchronization
(

11)

Summary of Contents for Modena FSW-301

Page 1: ...etting started 8 Batteries 8 Change settings 8 Remote unit setup 9 Clock 10 Alarm 12 Barometer 13 Weather forecast 14 Temperature humidity 15 Backlight 18 Reset system 18 Safety and care 18 Warnings 1...

Page 2: ...itoring indoor and wireless outdoor temperature and humidity measurement time keeping and alarm features into a single tool you can use from the convenience of your home Keep this manual handy as you...

Page 3: ...W DESCRIPTIONS 1 Memory view memory 15 2 Channel switch remote unit 9 15 3 Altitude 13 4 Snooze Light 13 18 5 Clock 10 6 Alarm 12 7 UP DOWN increase decrease setting or activate deactivate auto synchr...

Page 4: ...4 EN LEFT LCD DISPLAY DESCRIPTIONS 1 Low battery icon 8 2 Road conditions 14 3 Weather forecast 14 4 RF signal reception 10 5 Clock Calendar 10 6 Alarm Status Type 12 1 2 3 4 5 6...

Page 5: ...RIGHT LCD DISPLAY DESCRIPTIONS 1 Remote unit signal reception 9 15 2 Temperature 15 3 Temp Humidity trends 17 4 Remote unit low battery icon 8 5 Humidity Comfort level 17 6 Barometer 13 RH M 1 2 3 4...

Page 6: ...6 EN BACK VIEW DESCRIPTIONS 1 C F switch 9 16 2 Radio format switch 10 3 Barometer unit switch 13 4 Reset button 10 18 5 Battery compartment 8 5 1 2 3 4...

Page 7: ...ESCRIPTIONS 1 Temperature 15 2 Humidity and comfort level 17 3 Channel number 9 15 4 LED indicator 9 15 5 C F switch 9 16 6 Reset button 18 7 Channel switch 9 15 8 Batteries 8 9 Battery compartment 8...

Page 8: ...ch the correct polarity as shown in the battery compartment After you change the batteries press the RESET button with the point of a blunt object such as a ball point pen Insert the batteries in the...

Page 9: ...l remote units sold separately If you are using more than one remote unit be sure to select a different channel number for each unit INSTALLATION Mount the remote unit on a flat surface using the rece...

Page 10: ...during reception SET RADIO SIGNAL FORMAT The RADIO SIGNAL FORMAT switch is located in the battery compartment Select EU DCF or UK MSF Then press RESET to reset the unit Reception takes 2 10 minutes to...

Page 11: ...ou manually set the clock previous section 1 Press and hold CLOCK for 2 seconds to enter setting mode 2 Select the 12 24 hour format hour minute year date month format month date and NOTE Strong signa...

Page 12: ...M 1 Press and hold ALARM for 2 seconds to enter setting mode 2 Select the hour minute and alarm type for Beep Alarm or for Ferrari Engine Press UP or DOWN to change the setting Press ALARM to confirm...

Page 13: ...e next day press DOWN when the alarm time is displayed Press UP to activate the alarm again BAROMETER This product tracks barometric pressure changes over the past 24 hours to provide the weather fore...

Page 14: ...ays displayed Clear Partly Cloudy Cloudy Rainy ROAD CONDITIONS Based on the weather forecast a racing wheel icon will indicate the predicted road conditions Dry Slick Very Wet 1 The Barometer Unit swi...

Page 15: ...Press and hold MEMORY for 2 seconds until a beep sounds SELECT REMOTE UNIT CHANNEL Press CHANNEL to switch between CHANNEL 1 2 3 or indoor Or press and hold for 2 seconds to enter auto scan mode If y...

Page 16: ...between the indoor and outdoor units This is normal and does not affect the general performance of the product Reception will automatically resume once the interference ends Check the remote unit bat...

Page 17: ...mperature Relative Humidity Wet Any 70 Com 40 70 Dry Any 40 20 C 25 C 68 F 77 F TRENDS The trend arrow for the last 30 minutes always displays Indoor and outdoor temperature and humidity trends are sh...

Page 18: ...xpected e g unable to establish radio frequency link with remote unit or automatic clock etc This will return all settings to default value and you will lose all stored information minimum maximum tem...

Page 19: ...o not mix new and old batteries or batteries of different types Do not use rechargeable batteries with this product Remove the batteries if storing this product for a long period of time Do not scratc...

Page 20: ...eading 13 Calendar Strange date Change month language 11 Problem Symptom Remedy Clock Cannot 1 Adjust auto synch batteries 2 Press RESET 18 3 Manually activate auto synch 11 Remote Cannot locate Check...

Page 21: ...working 15 SPECIFICATIONS Main unit dimensions L x W x H 197 x 104 x 36 mm 7 76 x 4 09 x 1 42 inches Weight 386 grams 0 85 lbs with batteries Remote unit dimensions L x W x H 92 x 60 x 20 mm 3 6 x 2 4...

Page 22: ...ry Minimum maximum Trend 3 change per 30 minutes Barometer Unit mb hPa or inHg Range 500 to 1050 mb 14 77 to 31 01 inHg Resolution 1 mb 0 03 inHg Altitude 100 to 2500 meters 328 to 8202 feet Display R...

Page 23: ...wer Main unit 3 x UM 3 AA 1 5V alkaline batteries Remote unit 2 x UM 4 AAA 1 5V alkaline batteries ADDITIONAL RESOURCES Visit our website www oregonscientific com to learn more about your new product...

Page 24: ...t contains the approved transmitter module TX 01 and complies with the essential requirements ofArticle 3 of the R TTE 1999 5 EC Directives if used for its intended use and that the following standard...

Page 25: ...EN 25 Wireless Weather Station Model FSW 301 Modena User Manual...

Reviews: