RESET

Press and hold 

 and 

 together for 6 seconds to return the device to default 

settings.

MAINTAINANCE

Maintain the Rain Gauge

Cleaning the hole of the rain collector and the tipping bucket to maintain accuracy. 

Unscrew  the tipping bucket and clean the dirt with water periodically.

Maintain the Wind Sensor

If the wind cup doesn’t spin in the wind or does not spin as fast as they should.

Remove the wind cup and clear out all bugs, spider webs or debris.

NOTE

 Do not apply any fluid lubricant on the shaft and bearing. It will break the inner 

electronic components.

SPECIFICATIONS
BASE STATION

Dimension (L x W x H)

180 x 90 x 160 mm 

(7 x 3.54 x 6.3 inches)

Weight

427.5 g (0.94 lbs) without battery

Battery

   3 x 1.5 V AA batteries

AC/DC Adapter

Input: 100 – 240 V, 50-60 Hz 300 mA

Output: DC 5V, 1000 mA

ALL-IN-ONE SENSOR

Dimension (L x W x H)

385 x 195 x 315 mm

(15.16 x 7.68 x 12.4 inches)

Weight

1139 g (2.51 lbs) without battery

RF transmission frequency

EU: 868mhz, US: 915mhz

No. of channels

3

RF transmission 

range  

250 – 300 m (internal antenna)

Transmission Cycle

15 seconds

Battery 

4 x 1.5 V AA batteries 

Battery life

12 months 

BAROMETRIC PRESSURE

Unit

mb, inHg, mmHg and hPa

Measuring range

700 – 1050 hPa 

Accuracy

+/- 7 hP a

Altitude setting

Sea level 

User setting for offset pressure to sea level

Weather display

Sunny, Partly Cloudy, Cloudy,

Rainy and Snowy

INDOOR TEMPERATURE

Temperature unit

°C / °F (°C for EU, °F for US)

Measuring Range

-5 – 50 °C  (23 – 122 °F)

Accuracy

0 – 40 °C (32 – 104 °F): +/-1 °C (+/- 2 °F)

-5 – 0 °C (23 – 32.0 °F): +/-2 °C (+/- 4 °F)

40 – 50 °C (104 – 122 °F): +/-2 °C (+/- 4 °F)

Resolution

0.1 °C (0.2 °F)

Memory

Current, Min. and Max.

RELATIVE HUMIDITY

Measuring Range

10 % –

 95 % RH

Accuracy

40 % –

 80 % RH: +/-5 % RH

25 % –

 40 % RH and 80 % 

 90 % RH: +/-7 % RH

Resolution

1 %

Memory

Current, Min and Max

OUTDOOR TEMPERATURE

Temp. unit

°C / °F  (°C for EU, °F for US)

Measuring Range

-30 – 60 °C (-22 to 140 °F)

Accuracy

-20 – 0 °C: +/-2.0 °C (+/- 4.0 °F)

0 – 40 °C: +/-1.0 °C (+/- 2.0 °F)

40 – 50 °C: +/-2.0 °C (+/- 4.0 °F)

50 – 60 °C: +/- 3.0 °C (+/- 6.0 °F)

Temperature resolution 

0.1°C  (0.2 °F)

Memory

Current, Min and Max

WIND SENSOR

Wind speed unit

m/s, knots, kph, mph

Speed accuracy

2 – 10 m/s (+/-2 m/s)
10 – 56 m/s (+/-10 % m/s)

Direction resolution

22.5 degrees

Memory

Max wind speed

RAIN GAUGE

Rainfall unit

mm , inch (mm for EU, inch for US)

Rain rate unit

mm/hr and inch/hr

Measuring range for rainfall

0 mm to 9999 mm (0 – 393.6 inches)

Measuring range for rain rate

0, 0.04 in/hr (1mm/hr) to 

40 in/hr (1016 mm/hr)

Accuracy

0 – 15 mm (0 – 0.6”)/hr : +/-1 mm/hr (0.04”)

15 – 991 mm/hr (0.6 – 39”) : +/-10 %

Memory

Past 24 hrs, hourly from last memory reset

PRECAUTIONS

•  

Use only fresh batteries of the required size and type. Do not mix old and new 

batteries, different types of batteries.

•  

Do not dispose old batteries as unsorted municipal waste. Collection of such 

waste separately for special treatment is necessary.

•  

If you do not plan to use the product for a long time, remove the batteries. 

Batteries can leak chemicals that can damage electronic parts.

•   Do  not  subject  the  device  to  excessive  force,  shock,  dust,  temperature  or 

humidity.

•   Do not immerse the device in water. If you spill liquid over it, dry it immediately 

with a soft, lint-free cloth.

•   Do not clean the device with abrasive or corrosive materials.
•   Do not tamper with the device’s internal components. 

Doing so invalidates the 

warranty.

•   Images shown in this manual may differ from the actual display.
•   When  disposing  of  this  product,  ensure  it  is  collected  separately  for  special 

treatment.

•   The contents of this manual may not be reproduced without the permission of the 

manufacturer.

NOTE

  The  technical  specifications  for  this  product  and  the  contents  of  the  user 

manual are subject to change without notice.

NOTE

  Features and accessories will not be available in all countries. For more 

information, please contact your local retailer. To download an electronic version of 

the user manual, please visit 

http://global.oregonscientific.com/customerSupport.php

.

5

Summary of Contents for WMR500A

Page 1: ...USER MANUAL Professional all in one Weather Station Model WMR500A...

Page 2: ...EN 1 FR 7 ES 13...

Page 3: ...operation instructions please visit http global oregonscientific com customerSupport php PACKAGING CONTENTS 1 x Base Station 3 x AA UM 3 1 5V batteries 1x Power Adapter ALL IN ONE SENSOR 1x Main unit...

Page 4: ...4 Today max wind speed memory 5 Wind direction indicator 6 Today minimum wind chill 7 Wind speed level description D Clock Calender Weekday Moon Phase area 1 Clock 2 Date 3 Weekday 4 Moon phase ALL IN...

Page 5: ...ere South Northern Hemisphere Secure the all in one sensor connector in the desired location 1 Align the back of the sensor connector to an existing pole 2 Secure in place by inserting the ends of the...

Page 6: ...n To read the wind direction find the compass point is pointing to To select wind display mode Press MODE on wind area to toggle between GUST Gust AVG Average The wind level is shown by a series of te...

Page 7: ...Accuracy 20 0 C 2 0 C 4 0 F 0 40 C 1 0 C 2 0 F 40 50 C 2 0 C 4 0 F 50 60 C 3 0 C 6 0 F Temperature resolution 0 1 C 0 2 F Memory Current Min and Max WIND SENSOR Wind speed unit m s knots kph mph Spee...

Page 8: ...o radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient...

Page 9: ...us sur http global oregonscientific com customerSupport php CONTENU DE L EMBALLAGE 1 x Station de base 3 x Batteries AA UM 3 1 5 V 1x Adaptateur secteur CAPTEUR TOUT EN UN 1x Unit principale 1x Coupe...

Page 10: ...nots SPEED PAST24hrs TODAY MAX mbhPa mmHg inHg mm in hr TODAY MIN TODAY MAX 2 3 1 8 A B 4 5 6 7 C D HEAT INDEX TODAY MAX MIN HEAT INDEX TODAY MAX MIN DEW POINT TODAY MAX MIN DEW POINT TODAY MAX MIN 4...

Page 11: ...solaire Si vous r sidez Au Nord Dans l h misph re sud Au Sud Dans l h misph re Nord S curiser le connecteur du capteur tout en un dans la position souhait e 1 Aligner l arri re du connecteur de capteu...

Page 12: ...s REMARQUEREMARQUE L indice de chaleur fournit une indication sur le niveau de chaleur sur la base de la temp rature de l air et l humidit relative Le point de ros e renseigne sur la temp rature laque...

Page 13: ...e transmission RF 250 300 m antenne interne Cycle de transmission 15 secondes Piles 4 x 1 5 V AA Dur e de vie de la bat terie 12 mois PRESSION ATMOSPHERIQUE Unit mb inHg mmHg et hPa Plage de mesure 70...

Page 14: ...s pays Pour plus d information contacter le d taillant le plus proche Pour t l charger une version lectronique de ce mode d emploi veuillez visiter http global oregonscientific com customerSupport php...

Page 15: ...com customerSupport php CONTENIDO DEL PAQUETE 1 x Estaci n base 3x Pilas AA UM 3 de 1 5 V 1x Adaptador de alimentaci n SENSOR TODO EN UNO 1x Unidad principal 1x Cazoletas 1x Veleta 9 10 1 x Tornillo U...

Page 16: ...o MEDIA RACHAS 3 Lectura de velocidad del viento m s nudos kph o mph 4 M xima velocidad del viento en memoria de hoy 5 Indicador de direcci n del viento 6 Sensaci n t rmica m nima de hoy 7 Descripci n...

Page 17: ...impidan el flujo del viento para una medici n precisa Adem s coloque el sensor expuesto a la luz solar directa para una alimentaci n ptima del panel solar Orientaci n del panel solar Si reside en el N...

Page 18: ...1 Pulse SELECCIONAR varias veces para navegar hasta el icono del rea de humedad punto de condensaci n 2 Puse varias veces MODO para cambiar entre la humedad y el punto de condensaci n 3 Pulse M X M N...

Page 19: ...los rodamientos Posiblemente estropear a los componentes electr nicos internos ESPECIFICACIONES ESTACI N BASE Dimensiones L x An x Al 180 x 90 x 160 mm 7 x 3 54 x 6 3 pulgadas Peso 427 5 g 0 94 lbs s...

Page 20: ...ra general sino separadamente para recibir un tratamiento especial Los contenidos de este manual no pueden reproducirse sin permiso del fabricante NOTA La ficha t cnica de este producto y los contenid...

Page 21: ...2018 Oregon Scienti c All rights reserved...

Reviews: