background image

3

 GB

THE MAIN UNIT

The main unit gives you all the readings and controls. It should be
placed indoors.

The main unit is powered up by the 12V AC adapter.

To install it,

1. Position the main unit and other units within effective range

(100 meters).

2. Insert four UM3 or “AA”-sized alkaline batteries for backup

purpose.

3. Mount the main unit safely in place. Or use its table stand to

place it on a flat surface.

4. Connect the AC power adapter to the main unit and a wall socket.

5. Press the [RESET] button on the main unit to initiate operation.

The main unit will start searching for signals for about four minutes.
Upon successful reception, the readings will be displayed. The
main unit will update the readings at regular intervals.

Note: That if the main unit is operating solely on battery power, the
EL backlight and RS232 connection will be disabled.

LOW-BATTERY WARNING

There are low-battery indicators [

] for the main unit, rain

gauge, baro-thermo-hygrometer, thermo-hygrometer and optional
remote thermo and thermo-hygro sensors. Replace the batteries
when the respective indicators light up.

Note: The readings collected from the thermo-hygrometer and any
optional remote thermo and thermo-hygro sensors share the same
display window. The “OUT” and remote channel will share the same
low-battery indicator. When the battery level of the thermo-
hygrometer is low, the low-battery indicator will turn on. If it is one
of the optional remote sensors, the low-battery indicator will
blink. To locate the channel in question, press the window to scan
through all available devices. The low-battery indicator will stop
blinking if the battery level is low for that one.

SECTION 3 OPERATION

THE MAIN UNIT

A.

WEATHER    FORECAST    AND    BAROMETRIC    READING
WINDOW

B.

INDOOR    TEMPERATURE    WINDOW

C.

INDOOR    HUMIDITY    WINDOW

D.

OUTDOOR/CHANNEL    TEMPERATURE    WINDOW

E.

OUTDOOR/CHANNEL     HUMIDITY    WINDOW

F.

RAINFALL    WINDOW

G.

RF    CALENDAR    CLOCK    AND    DAILY    ALARM    WINDOW

H.

WIND SPEED    AND    DIRECTION    WINDOW

I.

CHANNEL    BUTTON

J.

MEMORY    BUTTON

K.

ALARM    BUTTON

L.

SET    BUTTON

M.

UNIT    BUTTON

N.

ALARM    ON/OFF    BUTTON

O.

[

I

 ]  BUTTON

P.

[

J

]   BUTTON

Q.

[ RESET]   BUTTON

R.

RS232  SERIAL  PORT

S.

DC 12V JACK

Summary of Contents for WMR928N

Page 1: ...by solar transmitter STR938 TheWMR928Ncansupportuptosevendifferentremoteinstruments You can also connect up to three optional thermo or thermo hygro sensors to the system Optional items include Therm...

Page 2: ...he rain collector to check the leveling 5 Use metal ring to adjust the leveling of the rain collector if necessary 6 Close the cover of the rain collector THE SOLAR TRANSMITTERS The solar transmitters...

Page 3: ...hygrometer and optional remote thermo and thermo hygro sensors Replace the batteries when the respective indicators light up Note The readings collected from the thermo hygrometer and any optional re...

Page 4: ...Use I and J to change to the desired setting 5 Press SET for minutes setting 6 Use I and J to change to the desired setting 7 Press SET to confirm Note the window will show if no alarm is armed Once s...

Page 5: ...eck the memory is clear INDOOR HUMIDITY The current indoor relative humidity taken by the indoor baro thermo hygrometer is displayed on the indoor hygrometer window Todisplaythemaximum minimumandcurre...

Page 6: ...larm setting will be displayed OUTDOOR AND CHANNEL HUMIDITY The relative humidity readings taken by the outdoor thermo hygrometer and separate thermo hygro sensors are displayed on the outdoor channel...

Page 7: ...receive the signal from those sensors 2 If you have disconnected signals you cannot clear the memory THE RESET BUTTON This button is only used when the system is operating in an unfavorable way or ma...

Page 8: ...attery for weather condition under 0 C STR938 Weight 290 g Dimension 115 L x 81 W x 138 H Power back up 2 x UM3 AA size alkaline battery recommend super lithium battery for weather condition under 0 C...

Page 9: ...9 GB COUNTRIES RTTE APPROVAL COMPLIED Austria Belgium Denmark Finland France Germany Greece Italy Luxembourg Netherlands Portugal Spain Sweden UK and Ireland...

Reviews: