Alarms
5 T
102
Alarm
code
Number of
times LED
blinks
Alarm type
Cause
Remedial action
How to reset
Motor
excitation *
44h
8
Encoder EEPROM
error
The data stored in the ABZO
sensor was damaged.
Execute either of the following
operations. If the same alarm is
still generated, the ABZO sensor
has been damaged. Contact your
nearest Oriental Motor sales
office.
•
Set phase Z again with the “ZSG-
PRESET” of the maintenance
command.
•
Execute the “Clear tripmeter” of
the maintenance command.
Turn on the
main power
supply and
control power
supply again
Non-
excitation
45h
8
Motor
combination error
A motor not allowed to
combine with the driver was
connected.
(Refer to p.104 for details.)
Check the motor model and the
driver model, and connect them
in a correct combination.
Turn on the
main power
supply and
control power
supply again
Non-
excitation
4Ah
7
Return-to-home
incomplete
Absolute positioning operation
was started in a state where the
coordinates had not been set.
Execute the position preset or
return-to-home operation.
Any of reset
operations
Excitation
60h
7
±LS both sides
active
•
When the “FW-LS/RV-LS input
action” parameter is set to “2:
Immediate stop with alarm”
or “3: Deceleration stop with
alarm,” both the FW-LS input
and the RV-LS input were
detected.
•
Return-to-home operation
was executed in a state where
both the FW-LS input and the
RV-LS input were detected.
Check the sensor logic installed
and the “Inverting mode”
parameter.
Any of reset
operations
Excitation
61h
7
Reverse ±LS
connection
The LS input opposite to the
operating direction was
detected while return-to-home
operation in the 2-sensor mode
or the 3-sensor mode was
performed.
Check the wiring of the sensor.
Any of reset
operations
Excitation
62h
7
Return-to-home
operation error
•
An unanticipated load was
applied while return-to-home
operation was performed.
•
The installation positions of
the FW-LS and RV-LS sensors
and the HOME sensor are
near to each other.
•
Position preset processing
upon completion of return-
to-home operation was failed.
•
In return-to-home operation
in the one-way rotation
mode, the HOME sensor was
exceeded while the motor
decelerated to a stop.
•
Check the load.
•
Reconsider the sensor
installation positions and the
starting direction of motor
operation.
•
See that a load exceeding the
maximum torque is not applied
upon completion of return-to-
home operation.
•
Reconsider the specifications of
the HOME sensor and the
"(HOME) Acceleration/
deceleration” parameter.
Any of reset
operations
Excitation
63h
7
No HOMES
The HOMES input was not
detected at a position between
the FW-LS input and the RV-LS
input while return-to-home
operation in the 3-sensor mode
was performed.
Install the HOME sensor at a
position between the FW-LS and
RV-LS sensors.
Any of reset
operations
Excitation
Summary of Contents for A Step AZ Series
Page 14: ...1 Introduction 14 ...
Page 64: ...3 Implicit communication 64 ...