Implicit message
3 I
54
When an area of assignable monitor is used
z
Area of Implicit message format used
Input (transfer from driver to scanner)
Byte
Description
40 to 55
Assignable monitor 0 to assignable monitor 3
z
Flow that data is read from
Scanner
Sets the “Assignable monitor address”
parameter.
Driver
The value of the parameter set in the “Assignable
monitor address” parameter is read every
communication cycle.
Communication cycle
Assignable monitor n *
* n: 0 to 3
z
Related parameters
Parameter ID
Name
Description
Initial value
Dec
Hex
25600
6400h
Assignable monitor
address 0
Sets the parameter ID to show on
the assignable monitor.
[Setting range]
Set from items of “3 Monitor
commands” on p.68
124: Driver temperature
25601
6401h
Assignable monitor
address 1
125: Motor temperature
25602
6402h
Assignable monitor
address 2
109: Cumulative load monitor
25603
6403h
Assignable monitor
address 3
127: Tripmeter