Parameter R/W commands
4 P
ar
88
Parameter ID
Name
Setting range
Initial
value
Update
Dec
Hex
1816
0718h
VA mode selection
0: Feedback speed attainment
(speed at feedback position)
1: Speed at command position
(only internal profile)
2: Speed at feedback position & command
position (only internal profile)
0
B
1817
0719h
VA detection speed range
1 to 200 r/min
30
B
1818
071Ah
MAREA output source
0: Feedback position (ON after operation)
1: Command position (ON after operation)
2: Feedback position
(MAREA output OFF at completion)
3: Command position
(MAREA output OFF at completion)
0
A
1856
0740h
AREA0 positive direction
position/offset
−2,147,483,648 to 2,147,483,647 steps
0
A
1857
0741h
AREA0 negative direction
position/detection range
1858
0742h
AREA1 positive direction
position/offset
1859
0743h
AREA1 negative direction
position/detection range
1860
0744h
AREA2 positive direction
position/offset
1861
0745h
AREA2 negative direction
position/detection range
1862
0746h
AREA3 positive direction
position/offset
1863
0747h
AREA3 negative direction
position/detection range
1864
0748h
AREA4 positive direction
position/offset
1865
0749h
AREA4 negative direction
position/detection range
1866
074Ah
AREA5 positive direction
position/offset
1867
074Bh
AREA5 negative direction
position/detection range
1868
074Ch
AREA6 positive direction
position/offset
1869
074Dh
AREA6 negative direction
position/detection range
1870
074Eh
AREA7 positive direction
position/offset
1871
074Fh
AREA7 negative direction
position/detection range
1872
0750h
AREA0 range setting mode
0: Range setting with absolute value
1: Offset/width setting from the target position
0
A
1873
0751h
AREA1 range setting mode
1874
0752h
AREA2 range setting mode
1875
0753h
AREA3 range setting mode
1876
0754h
AREA4 range setting mode
1877
0755h
AREA5 range setting mode
1878
0756h
AREA6 range setting mode
1879
0757h
AREA7 range setting mode