Addresses and codes lists
52
z
RS-485 communication setting parameter
Modbus
communication
Register address
Name
Description
Update
Industrial network
Command code
Upper
Lower
READ
WRITE
138Ch
(5004)
138Dh
(5005)
Communication error
detection (Modbus)
When the RS-485 communication error has
occurred for the set number of times, an
alarm of RS-485 communication error is
generated.
[Setting range]
0 (disable), 1 to 10 times
[Initial value: 3]
A
09C6h
(2502)
19C6h
(6598)
9-2
Addresses and codes not compatible with the mini Driver
Monitor command
Modbus communication
Register address
Name
Industrial network
Command code
Upper
Lower
014Eh
(334)
014Fh
(335)
ROT SW1
20A7h
(8359)
Power removal function setting parameters
All parameters are disabled (not compatible).
I/O parameters
Modbus communication
Register address
Name
Industrial network
Command code
Upper
Lower
READ
WRITE
0E18h
(3608)
0E19h
(3609)
PLS-XMODE pulse multiplying factor
070Ch
(1804)
170Ch
(5900)
0E26h
(3622)
0E27h
(3623)
PLS-LOST check algorithm
0713h
(1811)
1713h
(5907)
0E28h
(3624)
0E29h
(3625)
MON-REQ0 output data selection
0714h
(1812)
1714h
(5908)
0E2Ah
(3626)
0E2Bh
(3627)
MON-REQ1 output data selection
0715h
(1813)
1715h
(5909)
0E2Ch
(3628)
0E2Dh
(3629)
PLS-OUT output data selection
0716h
(1814)
1716h
(5910)
0E2Eh
(3630)
0E2Fh
(3631)
PLS-OUT maximum frequency
0717h
(1815)
1717h
(5911)
Direct I/O setting parameters
All parameters are disabled (not compatible).
Extended input setting parameters
All parameters are disabled (not compatible).
Differential output setting parameters
All parameters are disabled (not compatible).