background image

3

„

„

Connection cable (sold separately)

To connect the motor and driver, the dedicated connection cable (sold 

separately) is required.

The connection cables are provided up to 20 m (65.6  ft.).

Model name and type

Cable outlet direction

F

 

: 

Output shaft direction

B

 

: 

Opposite to output shaft 

        direction

V

 

: 

Vertical direction

Electromagnetic brake motor

Cable length

005

 : 

0.5 m (1.6 ft.)

010

 : 

1 m (3.3 ft.)

015

 : 

1.5 m (4.9 ft.)

020

 : 

2 m (6.6 ft.)

025

 : 

2.5 m (8.2 ft.)

030

 : 

3 m (9.8 ft.)

040

 : 

4 m (13.1 ft.)

050

 : 

5 m (16.4 ft.)

070

 : 

7 m (23.0 ft.)

100

 : 

10 m (32.8 ft.)

150

 : 

15 m (49.2 ft.)

200

 : 

20 m (65.6 ft.)

Output shaft direction:

CC_____

F

Opposite to output shaft
direction: 

CC_____

B

Vertical direction: 

CC_____

V

CC  005  KHBL  M  F

For the round shaft type motor, select the cable outlet direction in 

consideration of the installation.

„

„

Names of parts

Motor

The figure shows the 120W type motor.

Protective Earth Terminal

Mounting holes 

(4 places)

Motor

Gearhead

Output

shaft

Connector for cable 

connection

Electromagnetic brake

Connection cable (sold separately)

Connector for

motor connection

Ground terminal

Power connector (white)

Sensor connector (black)

Connectors for driver connection

Electromagnetic brake 

connector  (white)

Installation

This section explains the installation method of a load in addition to the 

installation location and installation method of the product.

„

„

 Installation location

Install the product in a well-ventilated location that provides easy access for 

inspection. The location must also satisfy the following conditions:

 

Indoors

 

Operating ambient temperature: 0 to +40 °C  (+32 to +104 °F) (non-freezing)

 

Operating ambient humidity 85% or less (non-condensing)

 

Area that is free of explosive atmosphere or toxic gas (such as sulfuric gas) or 
liquid

 

Area not exposed to direct sun

 

Area free of excessive amount of dust, iron particles or the like

 

Area free of excessive salt

 

Area not subject to continuous vibration or excessive shocks

 

Area free of excessive electromagnetic noise (from welders, power machinery, 
etc.)

 

Area free of radioactive materials, magnetic fields or vacuum

 

Altitude: Up to 1000 m (3300 ft.) above sea level

 

Area not subject to oil (oil droplets) or chemicals 

The motor can be used in an environment where it is splashed with water 

(excluding the part of the connectors for driver connection and the mounting 

surface of the round shaft type).  

However, do not use it under water or in high water pressure.

„

„

Installation method

 

z

Electromagnetic brake motor, combination type-parallel shaft 

gearhead

Secure the motor and gearhead through four mounting holes using the 

included mounting screw set.

Tighten the screws until no gap remains between the product and mounting 

plate.

Mounting screw set 

(included)

Motor

Gearhead

(L2)

L1

Model

Gear ratio

Hexagonal socket head 

screw

L2

[mm (in.)]

Tightening 

torque 

[N·m (lb-in)]

Screw 

size Material

L1

[mm (in.)]

BLM5120

5

 to 

20

M8 Stainless 

steel

70 (2.76)  11.5 (0.45)

12.0 (106)

30

 to 

100

85 (3.35) 13.5 (0.53)

200

90 (3.54) 12.5 (0.49)

BLM6200S

5

 to 

20

85 (3.35) 11 (0.43)

30

50

100 (3.94) 14 (0.55)

100

200

110 (4.33) 10 (0.39)

Summary of Contents for BLM Series

Page 1: ... so may result in fire electric shock or damage to equipment Do not apply any excessive force to the motor connector Doing so may result in fire electric shock or damage to equipment Do not forcibly bend pull or pinch the cable Doing so may result in fire electric shock or damage to equipment Do not remove the connector cap until the connection cable is connected so that the O ring of the connecto...

Page 2: ...ion to the motor output shaft Same direction as the motor output shaft when the gear ratio is 100 for the 200 W type z z Sliding noise of electromagnetic brake An electromagnetic brake motor may cause a sliding noise of the brake disk during operation There is no functional problem Insulation resistance measurement and dielectric strength test z z Do not conduct the insulation resistance measureme...

Page 3: ...ides easy access for inspection The location must also satisfy the following conditions Indoors Operating ambient temperature 0 to 40 C 32 to 104 F non freezing Operating ambient humidity 85 or less non condensing Area that is free of explosive atmosphere or toxic gas such as sulfuric gas or liquid Area not exposed to direct sun Area free of excessive amount of dust iron particles or the like Area...

Page 4: ...section thereby resulting in damage to the motor Installing a load When installing a load on the motor or gearhead pay attention to the following points Align the centerline of the output shaft with that of the load A key slot is provided on the output shaft of each combination type parallel shaft gearhead Form a key slot on the load side and secure the load using the parallel key Note When coupli...

Page 5: ...nection procedures of the motor and connection cable The following example explains using the connection cable of cable outlet in output shaft direction 1 Remove 2 Attach 3 Secure The connector cannot be inserted if the locking lever is turned down Be sure to turn down the locking lever till the position shown in the figure Secure the connector by turning down the locking lever completely Check th...

Page 6: ...heral equipment sold separately Peripheral equipment such as couplings and mounting brackets can be checked on the Oriental Motor Website About the mounting bracket SOL of the motor Secure the motor and mounting bracket so that the connector for motor connection is positioned other than the installation surface side of the mounting bracket Installation in a state where the motor connector is posit...

Page 7: ...ls for the motor or connection cable and driver securely Isolate the connection cable power supply cable and other drive cables from the signal cables by means of double insulation Applicable standards EN 60034 1 EN 60034 5 EN 60664 1 Installation conditions EN Standard To be incorporated in equipment Overvoltage category ІІ Pollution degree 3 Protection against electric shock Class І equipment Th...

Page 8: ...n January 2020 Technical Support Tel 800 468 3982 8 30 A M to 5 00 P M P S T M F 7 30 A M to 5 00 P M C S T M F www orientalmotor com Schiessstraße 74 40549 Düsseldorf Germany Technical Support Tel 00 800 22 55 66 22 www orientalmotor de Tel 01256 347090 www oriental motor co uk Tel 01 47 86 97 50 www orientalmotor fr Tel 02 93906346 www orientalmotor it Tel 55 11 3266 6018 www orientalmotor com b...

Reviews: