5

Connection

„

„

Connecting the motor and driver

Connect the motor and driver using the connection cable (sold separately).

There are three types of connection cables which cable outlet directions are 

different.

To driver

Connection cable

Motor

Check the operating manual 

of the driver for how to 

ground.

Cable outlet opposite 

to output shaft direction

Cable outlet in output 

shaft direction

[ Cable outlet direction ]

Cable outlet in 

vertical direction

Cable outlet in output shaft direction

CC_____

F

CC_____

B

CC_____

V

Note

Use the connection cable that the label for electromagnetic 

brake motor is attached. Failure to do so may result in damage to 

equipment.

Label for electromagnetic 

brake motor

For

BRAKE

MOTOR

„

„

Connection procedures of the motor and connection cable

The following example explains using the connection cable of "cable outlet in 

output shaft direction."

1

Remove

2

Attach

3

Secure

The connector cannot be inserted  

if the locking lever is turned down.

Be sure to turn down

the locking lever till

the position shown

in the figure.

Secure the connector by turning

down the locking lever completely.

Check the cable outlet direction and insert the connector securely.

Secure the cable with the locking lever so that the cable does not 

come off.

Connector cap

Locking lever

Position of locking lever

Note

Do not lift up the product by 

holding the connection cable. 

Doing so may cause damage to 

the product.

„

„

Detaching the connection cable

If the locking lever is turned up, the cable can be detached.

Up to two pieces of the connection cables for relay can be connected.

Check the operating manual included with the driver.

Summary of Contents for BLM Series

Page 1: ... so may result in fire electric shock or damage to equipment Do not apply any excessive force to the motor connector Doing so may result in fire electric shock or damage to equipment Do not forcibly bend pull or pinch the cable Doing so may result in fire electric shock or damage to equipment Do not remove the connector cap until the connection cable is connected so that the O ring of the connecto...

Page 2: ...ion to the motor output shaft Same direction as the motor output shaft when the gear ratio is 100 for the 200 W type z z Sliding noise of electromagnetic brake An electromagnetic brake motor may cause a sliding noise of the brake disk during operation There is no functional problem Insulation resistance measurement and dielectric strength test z z Do not conduct the insulation resistance measureme...

Page 3: ...ides easy access for inspection The location must also satisfy the following conditions Indoors Operating ambient temperature 0 to 40 C 32 to 104 F non freezing Operating ambient humidity 85 or less non condensing Area that is free of explosive atmosphere or toxic gas such as sulfuric gas or liquid Area not exposed to direct sun Area free of excessive amount of dust iron particles or the like Area...

Page 4: ...section thereby resulting in damage to the motor Installing a load When installing a load on the motor or gearhead pay attention to the following points Align the centerline of the output shaft with that of the load A key slot is provided on the output shaft of each combination type parallel shaft gearhead Form a key slot on the load side and secure the load using the parallel key Note When coupli...

Page 5: ...nection procedures of the motor and connection cable The following example explains using the connection cable of cable outlet in output shaft direction 1 Remove 2 Attach 3 Secure The connector cannot be inserted if the locking lever is turned down Be sure to turn down the locking lever till the position shown in the figure Secure the connector by turning down the locking lever completely Check th...

Page 6: ...heral equipment sold separately Peripheral equipment such as couplings and mounting brackets can be checked on the Oriental Motor Website About the mounting bracket SOL of the motor Secure the motor and mounting bracket so that the connector for motor connection is positioned other than the installation surface side of the mounting bracket Installation in a state where the motor connector is posit...

Page 7: ...ls for the motor or connection cable and driver securely Isolate the connection cable power supply cable and other drive cables from the signal cables by means of double insulation Applicable standards EN 60034 1 EN 60034 5 EN 60664 1 Installation conditions EN Standard To be incorporated in equipment Overvoltage category ІІ Pollution degree 3 Protection against electric shock Class І equipment Th...

Page 8: ...n January 2020 Technical Support Tel 800 468 3982 8 30 A M to 5 00 P M P S T M F 7 30 A M to 5 00 P M C S T M F www orientalmotor com Schiessstraße 74 40549 Düsseldorf Germany Technical Support Tel 00 800 22 55 66 22 www orientalmotor de Tel 01256 347090 www oriental motor co uk Tel 01 47 86 97 50 www orientalmotor fr Tel 02 93906346 www orientalmotor it Tel 55 11 3266 6018 www orientalmotor com b...

Reviews: