4 Types and functions of operations
−
31
−
4.5 Continuous operation (controller mode only)
When the FWD input is ON, the actuator moves continuously in the + coordinate direction. When the RVS
input is ON, the actuator moves continuously in the – coordinate direction.
Note
•
Only the operating speed can be changed during operation by selecting different
operation data.
•
Even if different operation data is selected while operating, the
acceleration/deceleration cannot be changed.
•
Example of operating data setting
•
Example of speed parameter setting
Data No.
Operating speed
Acceleration/
Deceleration No.
Starting
speed
Common operating speed
1
30 mm/s (1.18 in/s)
0
2
50 mm/s (1.97 in/s)
3
6 mm/s
(0.24 in/s)
60 mm/s
(2.36 in/s)
3
10 mm/s (0.39 in/s)
1
4 Not
set
2
•
Execution example 1
M0 to M5 input
FWD input
RVS input
Operating
speed
30 mm/s
(1.18 in/s)
Operating
speed
50 mm/s
(1.97 in/s)
Common operating speed
60 mm/s (2.36 in/s)
Operating speed
50 mm/s (1.97 in/s)
Operating speed
10 mm/s
(0.39 in/s)
+ coordinate direction
- coordinate direction
No.1
No.2
No.3
No.2
No.0
Acceleration No.0
Acceleration
No.3
Acceleration
No.0
•
Execution example 2
M0 to M5 input
FWD input
RVS input
Re-acceleration
Both the FWD and
RVS turn ON
simultaneously
= Deceleration stop
Data number for
which no data has
been set is selected
= Deceleration stop
Operating
speed
50 mm/s
(1.97 in/s)
Operating speed
30 mm/s (1.18 in/s)
+ coordinate direction
- coordinate direction
No.2
No.1
No.4
Acceleration No.3
Acceleration
No.0
Summary of Contents for EZ limo ESMC-A2