1 Introduction
−
3
−
1 Introduction
1.1 Important
note
Be sure to confirm that the motorized actuator model shown on the controller key is the same as the model of
the motorized actuator connected to the controller. If the two numbers do not match, the motorized actuator
cannot be operated according to the specification. For details, refer to 1.6, “Controller key” on p.7.
Controller key
Motorized actuator model
1.2 Overview of the product
This linear motion controller (hereinafter referred to as “controller”) is a dedicated controller for motorized
actuators.
In the controller, the specification of the combined motorized actuator is set automatically based on the datas
stored in the controller key.
You can select desired settings for the following items using the mode switches on the controller.
•
Controller mode/driver mode
Controller mode: The motorized actuator is operated in accordance with the operating data stored in the
controller.
Driver mode:
The motorized actuator is operated by means of externally input pulses.
•
Absolute mode/incremental mode
Absolute mode:
An optional battery (sold separately) is used to retain the current position even after the
power is turned off.
Incremental mode: Since the current position is not retained, return-to-home operation must be performed
after the power is input.
1.3 System configuration
Controller key
DC power supply
Motorized actuator
Main power supply
Emergency stop circuit
Battery
∗
1
Host controller
User I/O
Sensor I/O
Sensor
∗
2
Teaching
pendant
EZT1
or
Motor cable
indicates an optional accessory
(sold separately).
Data editing software
EZED2
(The software comes with a PC interface cable.)
∗1
Absolute mode only.
∗2
Sensors are optional (sold separately) on the
EZS
Ⅱ
series and
ESR
series.
Summary of Contents for EZ limo ESMC-A2