1 Introduction
−
4
−
1.4 Compliance with the EC Directives
The controllers bear the CE Marking indicating their compliance with the Low Voltage and EMC Directives,
based on combinations with the products specified below.
The controllers do not comply with the EC Directives if combined with other products.
•
Installation conditions
Controller, teaching pendant
Controller is to be used as a component within other equipment.
Models
ESMC-K2
ESMC-A2
,
ESMC-C2
EZT1
Overvoltage category
Ⅰ
Ⅱ
−
Pollution degree
2
Protection against electric
shock
Class
Ⅲ
Class
Ⅰ
−
Degree of protection
IP10
IP40
Motorized actuator
Models
EZSM
K
∗
EZCM
K
EZAM
K
EZSM
A
∗
,
EZSM
C
∗
EZCM
A
,
EZCM
C
EZAM
A
,
EZAM
C
SPFM
K
SPVM
K
SPRM
K
Overvoltage category
Ⅰ
Ⅱ
Ⅰ
Pollution degree
2
2
Protection against electric
shock
Class
Ⅲ
Class
Ⅰ
Class
Ⅲ
Degree of protection
IP20
−
Noise level
71 dB
71 dB
∗
Excluding the
EZS
Ⅱ
Series Clean Room Use motorized linear slides.
•
Environmental condition
Operating environment
Storage environment Shipping
environment
Ambient
temperature
0 to +40 °C (+32 to +104 °F)
(non-freezing)
–25 to +70 °C (–77 to +158 °F) (non-freezing)
Ambient
humidity
85% or less (non-condensing)
Altitude
Up to 1000 m (3300 ft.) above sea level
Up to 3000 m (10000 ft.)
above sea level
Surrounding
atmosphere
•
Area that is free from an explosive nature or toxic gas (such as sulfuric gas) or liquid
•
Area not exposed to direct sun
•
Area free of excessive amount dust, iron particles or the like
•
Area not subject to splashing water (storms, water droplets), oil (oil droplets) or other
liquids
•
Area free of excessive salt
•
Area not subject to continuous vibration or excessive shocks
•
Area free of excessive electromagnetic noise (from welders, power machinery, etc.)
•
Area free of radioactive materials, magnetic fields or vacuum
Low Voltage Directive
Model Applicable
Standards
ESMC-K2
Not applicable, because the input power supply
voltage is 24 VDC
ESMC-A2
,
ESMC-C2
EN
50178
EZSM
K
∗
,
EZCM
K
,
EZAM
K
Not applicable, because the input power supply
voltage is 24 VDC
EZSM
A
∗
,
EZSM
C
∗
EZCM
A
,
EZCM
C
EZAM
A
,
EZAM
C
EN 60950, EN 60034-1, EN 60034-5, EN 60664-1
EZT1
EN 60950, EN 60204-1
∗
Excluding the
EZS
Ⅱ
Series Clean Room Use motorized linear slides.
Summary of Contents for EZ limo ESMC-A2