Introduction
▌
2
1 Introduction
Before use
Only qualifi ed personnel of electrical and mechanical engineering should work with the product.
Use the product correctly after thoroughly reading the “2 Safety precautions” on p.5. In addition, be sure to
observe the contents described in warning, caution, and note in this manual.
The product described in this manual has been designed and manufactured to be incorporated in general industrial
equipment. Do not use for any other purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused
through failure to observe this warning.
This manual, unless otherwise noted, explains using fi gures of the built-in controller type driver.
Operating Manuals for the
AZ
Series
Operating manuals for the
AZ
Series DC power input type are listed below.
After reading these manuals, keep them in a convenient place so that you can reference them at any time.
The "
AZ
Series Function Edition" does not come with the product. For details, contact your nearest Oriental Motor
sales offi
ce or download from Oriental Motor Website download page.
Type of operating manual
Description of operating manual
OPERATING MANUAL Driver
(this document)
This manual explains the functions as well as the installation/connection method
and others for the driver.
AZ
Series Function Edition
This manual explains driver functions, data setting methods, operating methods
and others which are not described in the operating manual.
General specifi cations
Degree of protection
IP10
Operation
environment
Ambient temperature
0 to +50 °C (+32 to +122 °F) (non-freezing)
Humidity
85% or less (non-condensing)
Altitude
Up to 1000 m (3300 ft.) above sea level
Surrounding atmosphere
No corrosive gas, dust, water or oil
Storage
environment,
Shipping
environment
Ambient temperature
−25 to +70 °C (−13 to +158 °F) (non-freezing)
Humidity
85% or less (non-condensing)
Altitude
Up to 3000 m (10000 ft.) above sea level
Surrounding atmosphere
No corrosive gas, dust, water or oil
Insulation resistance
100 MΩ or more when 500 VDC megger is applied between
the following places:
· PE terminal - Power supply terminals
RS-485 communication specifi cation
Electrical characteristics
Compliant with EIA-485, straight cable
Use a twist pair cable (TIA/EIA-568B CAT5e or higher is recommended) and keep
the total wiring distance up to 50 m (164 ft.). *
Communication mode
Half-duplex communication
Asynchronous mode (data: 8 bits, stop bit: 1 bit/2 bits, parity: none/even
number/odd number)
Transmission rate
Selectable from 9,600 bps, 19,200 bps, 38,400 bps, 57,600 bps, 115,200 bps, and
230,400 bps
Protocol
Modbus RTU mode
Number of connectable units
Up to 31 units can be connected to one master controller.
* If the motor cable or power supply cable generates an undesirable amount of noise depending on the wiring or
confi guration, shield the cable or install a ferrite core.