Guidance
▌
40
10-6 Timing
chart
This section shows ON/OFF timings for input signals and output signals.
For details, check with the
AZ
Series Function Edition.
Positioning operation
Built-in controller type
Positioning operation can be performed with selecting the operation data.
1. Turn on the power supply.
The READY output turns ON.
2. Check the READY output is turned ON and turn the START input ON by selecting the operation data number with
the M0 to M2 outputs.
The motor will start positioning operation.
3. Check the READY output has been turned OFF and turn the START input OFF.
When the operation is complete, the READY output will turn ON.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
MOVE output
M0 to M2 input
START input
READY output
ON
OFF
IN-POS output
1
2
2
3
3
Motor operation
Power supply
Pulse input type with RS-485 communication interface, pulse input type
Positioning operation is performed by inputting pulses.
1. Turn on the power supply.
The READY output and PLS-RDY output turn ON.
2. Check the PLS-RDY output has been turned ON and input pulses.
The motor will start positioning operation.
When the pulse is stopped inputting and the operation is complete, the READY output will turn ON.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Motor operation
Power supply
Pulse input
PLS-RDY output
READY output
ON
OFF
IN-POS output
ON
OFF
MOVE output
1
2
2