Inspection
−37−
11 Inspection
It is recommended that periodic inspections for the items listed below are conducted after each operation of the motor.
If an abnormal condition is noted, discontinue any use and contact your nearest Oriental Motor sales office.
Note
•
Perform the insulation resistance test or dielectric strength test separately on the motor and the
driver. Performing the insulation resistance test or dielectric strength test with the motor and
driver connected may result in damage to the product.
•
The driver uses semiconductor elements, so be extremely careful when handling them.
Electrostatic discharge can damage the driver.
During inspection
•
Are any of the motor (gearhead) mounting screws loose?
•
Are there any abnormal noises in the motor bearings (ball bearings) or other moving parts?
•
Are there any abnormal noises in the bearing (ball bearing) and gear meshing parts of the gearhead?
•
Are the motor output shaft and load shaft out of alignment?
•
Are there any scratches, signs of stress or loose driver connections in the cable?
•
Are the openings in the driver blocked?
•
Are any of the mounting screws or main power input unit of the driver loose?
•
Are there any strange smells or appearances within the driver?