IDS-141A_181A Series
User’s Manual
33
ORing Industrial Networking Corp.
Figure 5-18 Notification
The following table describes the labels in this screen.
Label
Description
DCD changed
When DCD (Data Carrier Detect) signal changes, it indicates that the modem
connection status has changed. Notification will be sent.
DSR changed
When DSR (Data Set Ready) signal changes, it indicates that the data communication
equipment is powered off. A Notification will be sent.
CTS changed
When CTS (Clear To Send) signal changes, it indicates that the transmission between
computer and DCE can proceed. A notification will be sent.
Port connected
In TCP Server Mode, when the device accepts an incoming TCP connection, this event
will be trigger. In TCP Client Mode, when the device has connected to the remote host,
this event will be trigger. In Virtual COM Mode, Virtual COM is ready to use. A
notification will be sent.
Port disconnected
In TCP Server/Client Mode, when the device lost the TCP link, this event will be trigger.
In Virtual COM Mode, When Virtual COM is not available, this event will be trigger. A
notification will be sent.
Table 5-11 Notification