Q I G
Quick Installation Guide
PRINTED ON RECYCLED PAPER
Q
uick
I
nstallation
G
uide
Q I G
DIP Switch Setting
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1:
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2:
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1
PWR-2 1A@24V
V2- V2+ V1- V1+
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer
to the following tablet for LED indication.
Specifications
LED
Color
Status
Description
P1
Green
On
DC power 1 activated
P2
Green
On
DC power 2 activated
Fault
Amber
On
Power failure
10/100Base-T(X) Ethernet ports
LNK/ACT
Green
On
Port is linked
Duplex
Amber
On
Port link up for full duplex
Off
Port link up for half duplex
For pin assignments for different types of cables, please refer to the following
tables.
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
Version 2.1
DIP-2
OFF
OFF
ON
DIP-1
Power failure relay alarm disabled
PWR-1 failure, relay alarm enabled
PWR-2 failure, relay alarm enabled
OFF
ON
OFF
Description
ON
PWR-1 or PWR-2 failure,
relay alarm enabled
ON
10/100Base-T(X) RJ-45
Pin Number
Assignment
1
TD+
2
TD-
3
RD+
4
Not used
5
Not used
6
RD-
7
Not used
8
Not used
Note:
“+” and “-” signs represent the polarity of the wires
that make up each wire pair
.
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
LED Indicators
Green: Power LED x2
Power indicator
10/100Base-T(X) Port in RJ45
Auto MDI/MDIX
IEEE 802.3 for 10Base-T,
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
Processing
Store-and-Forward
Environmental
-40 to 85 C (-40 to 185 F)
o
o
Storage Temperature
Operating Temperature
5% to 95% Non-condensing
Operating Humidity
Regulatory approvals
CE EMC (EN 55024, EN 55032), FCC Part 15 B
EMC
EN 55024 (IEC/EN 61000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (RS: 3V)
IEC/EN 61000-4-4 (EFT Power 0.5KV, Signal 0.5KV),
IEC/EN 61000-4-5 (Surge: Power 0.5KV, Signal 1KV), IEC/EN 61000-4-6 (CS: 3V),
IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2-27
Shock
IEC60068-2-32
IEC60068-2-6
Vibration
Free Fall
MTBF
2,439,118hrs
-40 to 75 C (-40 to 167 F)
o
o
Amber: Indicate PWR1 or PWR2 failure
Fault indicator
Fault contact
Relay
Relay output to carry capacity of 1A at 24 VDC
Power
Redundant Input power
Power consumption(Typ.)
<3.7Watts, 0.23A-0.07A
Overload current protection
Reverse polarity protection
Present
Present
Physical Characteristic
Enclosure
IP-30 Metal
Dimension (W x D x H)
Weight (g)
391 g
Dual 12~48VDC on 6-pin terminal block
26.1(W)x94.9(D)x144.3(H) mm (1.03x3.74x5.68inch.)
10/100Base-T(X) RJ45 Port
Indicator
Upper LED for Link/Act indicator: Green for Link/Act
Lower LED for duplex indicator, Amber for full duplex, off for half duplex
EN60950-1(LVD)
Safety
IES-1080A
8
MAC Table
1K
Packet buffer
448 Bits
Warranty
5 years
Switch Properties
Switching latency: 7 us
Switching bandwidth: 1.6Gbps
Throughput (packet per second): 1.19Mpps@64Bytes packet
Hardware Version
V2.0
EN 55032, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A
EMI
Industrial Unmanaged Switch
SWITCH
I N D U S T R I A L
IES-1080A
IES-1080A