IES-P3073GC Series User Manual
ORing Industrial Networking Corp
1
LED Indicators
Power Indicator
Green : Power LED x 3
R.M. Indicator
Green : Indicate system operated in O-Ring master mode
Fault Indicator
Amber : Indicate unexpected event occurred
10/100Base-T(X) RJ45 Port Indicator
Green for port Link/Act. Amber for Duplex/Collision
10/100/1000Base-T(X) RJ45 Port
Indicator
Green for port Link/Act. Amber for 100Mbps indicator
100/1000Base-X SFP Port Indicator
Green for port Link/Act.
Fault contact
Relay
Relay output to carry capacity of 1A at 24VDC
Power
Redundant Input Power
Dual power inputs. 20~72VDC on dual 2-pin
terminal block
Dual power inputs. 85~264VAC/88~373VDC on dual
3-pin terminal block
Power Consumption (Typ.)
12 Watts
12 Watts
Overload Current Protection
Present
Reverse Polarity Protection
Present on terminal block
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
96.4 (W) x 145.5 (D) x 154 (H)mm
3.8 (W) x 5.73 (D) x 6.06 (H)inch
96.4 (W) x 145.5 (D) x 154 (H)mm
3.8 (W) x 5.73 (D) x 6.06 (H)inch
Weight (g)
1415 g
1935 g
Environmental
Storage Temperature
-40 to 85
o
C (-40 to 185
o
F)
Operating Temperature
-40 to 85
o
C (-40 to 185
o
F)
Operating Humidity
5% to 95% Non-condensing
Regulatory approvals
Power Automation
IEC 61850-3, IEEE 1613
EMI
FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2, EN55011, EN50121-4)
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS),
EN61000-4-8, EN61000-4-11
Shock
IEC60068-2-27
Free Fall
IEC60068-2-32
Vibration
IEC60068-2-6
Safety
EN 60950-1
Warranty