IGMG-P-D4G
User Manual
ORing Industrial Networking Corp. 31
RTU/ASCII Master Mode
The ModBus RTU Master mode is used to connect to the serial device which runs as
RTU slave. Serial port server will connect to the remote TCP Server, which is also called
Modbus TCP Slave.
Label
Description
Destination Host
Set the IP address of host and the port number of data port. .
Idle Timeout
When serial port stops data transmission for a defined period of
time, the connection will be closed and the port will be freed and
try to connect with other hosts.
0
indicates disabling this function
and is also the factory default value. If multilink is configured,
only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check packages in each
defined time interval to remote host to check the TCP connection.
If the TCP connection is not alive, the connection will be closed
and the port will be freed.
0
indicates disabling this function.
Factory default is
0
.