IMG-111 User Manual
ORing Industrial Networking Corp. 14
Label
Description
Port Alias
Remark the port to hint the connected device
Interface
RS422 / RS485(2-wires) / RS485(4-wires)
Baud rate
110bps/300bps/1200bps/2400bps/4800bps/9600bps/19200bps/
38400bps/57600bps/115200bps
Data Bits
5, 6, 7, 8
Stop Bits
1, 2 (1.5)
Parity
No, Even, Odd, Mark, Space
Flow Control
No, XON/XOFF
Force TX Interval Time
Force TX interval time is to specify the timeout when no data has
been transmitted. When the timeout is reached or TX buffer is full
(4K Bytes), the queued data will be sent. 0 means disable.
Factory default value is 0
Performance
Throughput
: This mode is optimized for the highest transmission
speed.
Latency
: This mode is optimized for the shortest response time.
Port Configuration
Label
Description
Serial to
Ethernet
Flush Data Buffer After
:
The received data will be queued in the buffer until all the delimiters are
matched. When the buffer is full (4K Bytes) or after "flush S2E data
buffer" timeout, the data will also be sent. You can set the time from 0
to 65535 second.