IMG-111 User Manual
ORing Industrial Networking Corp. 16
defined time interval (Alive Check) to remote host to check the
TCP connection. If the TCP connection is not alive, the
connection will be closed and the port will be freed.
0
indicate
disable this function. Factory default is 0.
Max Connection
The number of maximum connections can be supported. The
maximum value is
5
, default values is
1
.
*Not allowed to mapping Virtual COM from web
TCP Server Mode
In TCP Server mode, IMG is configured with a unique port combination on a TCP/IP network.
In this case, IMG waits passively to be contacted by the device. After the device establishes a
connection with the serial device, it can then proceed with data transmission. The TCP
Server mode also supports up to 5 simultaneous connections, so that multiple device can
receive data from the same serial device at the same time.
Label
Description
Data Encryption
Use SSL to encrypt data.
TCP Server Port
Set the port number for data transmission.
Idle Timeout
When serial port stops data transmission for a defined period of
time (Idle Timeout), the connection will be closed and the port will
be freed and try to connect with other hosts.
0
indicate disable this
function. Factory default value is
0
. If Multilink is configured,
only the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each
defined time interval (Alive Check) to remote host to check the
TCP connection. If the TCP connection is not alive, the
Summary of Contents for IMG-111